 设  计  计  算   冷凝器大直径接管的应力计算与强度分析 南京工业大学化工机械研究所  景国泉  沈士明 摘  要 :运用有限元方法对具有大直径接管的冷凝器进行了应力分析, 得到了接管部位的应力分布, 并按照分析设计原理进行了强度评定, 针对原设计中的不足, 进行了多方案计算, 为该结构的改进 提供了依据 。 关键词 :大直径接管; 有限元; 应力计算; 强度分析 + ( ) 中图分类号 :TQ0516 1   文献标识码 :A   文章编号 :1001 - 4837 2002 05 - 0012 - 03 Stress Calculation and Strength Analysis for Large Dia meter Nozzle in Condenser Nanj ing University of Technology  JING Guoquan  SHEN Shiming Abstract :In this paper a stress analysis for a condenser with large diameter nozzle had been made by finite ele ment method . The pattern of the stress distribution of the nozzle region was obtained from the calculation . Ac cording to the analysis design principle the strength of the large diameter nozzle was evaluated . As to the lack of original design , multi - variant calculation had been carried on which gave a basis of improving the struc ture . Key words :large diameter nozzle ; finite element ; stress calculation ; strength analysis 凝器接管部位详尽的应力场和最大应力发生部位,   1  前言 并运用分析设计原理进行结构的强度评定, 发现原 圆柱壳开孔接管是压力容器中的一种最常见的 设计结构的强度不足, 在此基础上本文进行了多方 结构, 而大开孔接管在压力容器设计中也经常遇见 。 案的分析, 从而提出了较佳的方案, 为该设备的安全 开孔会在壳体上造成局部高应力, 从而严重影响了 设计提供了依据 。 壳体的承载能力 。有关该部位的应力计算与强度分   2  内压作用下有限元计算模型 析国内外研究人员做过了大量的工作[ 1~8] 。通常对 开孔结构的强度评定常采用一些经验公式来估算接 21  设计参数 管部位局部应力的最大值, 然后将最大应力值与规 冷凝器为 U 形管式, 设计压力为 06MPa , 水压 范所规定的极限值加以比较的方法或采用 WRC — 试验压力为 075MPa , 筒体与接管材料均为 304L , [ 9] ( ) 5 μ