水环热泵空调系统的设计与安装(国外英文资料) Water loop heat pump air conditioning system design includes the choice of air conditioning load calculation, unit, cooling tower, auxiliary heat source, heat storage water tank design, selection of circulating pump and the design of automatic control, etc. Water loop heat pump systems adopt independent regional control and combined control system of central control system, including control of heat pump units, circulating water system, central control. The key to the installation of water ring heat pump air conditioning system is to control the spread of noise, and mainly pay attention to the installation of the unit, wind pipe, tuyere installation, water pipe installation and so on. Key words: water ring heat pump [16] load computing [7] cooling tower [39] Water loop heat pump system design includes load calculation, the choice of units, cooling tower, auxiliary heat source, heat storage water tank design, selection of circulating pump and the design of automatic control, etc. Load calculation The calculation of cold loads The cold load calculation is the same as the normal air conditioning system. Heat load calculation Because the water loop heat pump air conditioning system is a heat recovery system, winter is running, in the heat pump units to the water loop heat release, the outer zone loop heat pump units from water absorption of heat. Therefore, when calculating the winter load of the water ring heat pump air conditioning system, it should not be the normal air-conditioning system. Type: QE -- the external heat load, KW; QI -- the internal heat load, KW; QL, E, QG, E -- heat loss in the outer region, heat outside, KW; QL, I, QG, I - heat loss in the inner region, heat in the inner region, KW; QR, E -- the heat pump in the outer region pumps heat, KW; QA, I -- heat pumps in the inner region, KW; COPE - heat pump coefficient of heat pump units in winter conditions; COPI - the refrigerating factor of the heat pump unit of the launching ri

文档评论(0)

f8r9t5c + 关注
实名认证
内容提供者

该用户很懒,什么也没介绍

版权声明书
用户编号:8000054077000003

1亿VIP精品文档

相关文档