结构专业问题(国外英文资料).doc

  1. 1、本文档共16页,可阅读全部内容。
  2. 2、原创力文档(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。
  3. 3、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载
  4. 4、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
查看更多
结构专业问题(国外英文资料)

结构专业问题(国外英文资料) List of frequently asked questions of structural specialty Serial number of common problems, relevant specifications, plans, institutions, comments Specification number entry A load and a calculation section 1 the influence of accidental eccentricity is not taken into account when calculating one-way seismic action. JGJ3-2002 3.3.3 rectification 2 for high buildings which are especially important or sensitive to wind load, the basic wind pressure is not used as the wind pressure value in the 100 year recurrence period. JGJ3-2002 3.2.2 rectification 3 high building fire evacuation staircase, load value is less than 3.5kn/m2. GB50009-2001 4.1.1 rectification 4 on roof live load still with the old standard value of 1.5 kn/m2, on non upper roof should be construction professional confirmation, sometimes structure according to non upper human roof design, construction for upper roof. GB50009-2001 4.3.1 rectification 5 of hotels, hospitals and other local toilet partition layout is dense, not converted into equivalent load according to the actual input, such as the wall weight per meter 1/3 reduced survival load value is too small, and more than 1 kn/m2. GB50009-2001 4.1.1 note 5 rectification 6 the ratio of the first natural vibration period Tt and the libration of the first natural vibration period T1 to the plane irregular structure and the main torsion of the structure is higher than 0.9, and the B height is greater than 0.85. JGJ3-2002 4.3.5 rectification 7 the structure of mass and stiffness distribution is obviously asymmetric and uneven, and it is still calculated by one-way horizontal seismic action. JGJ3-2002 3.3.2 rectification 8 for the V, Y, arc and well shaped flat buildings, the shape factor of wind load is still 1.3. JGJ3-2002 3.2.5 audit opinion 9, the stiffness coefficient of the beam in the cast-in-place floor is 1, which makes the support of the beam slightly smaller. JGJ3-2002 5.2.2 audit opinion 107-9 degrees, the frame structure has n

文档评论(0)

f8r9t5c + 关注
实名认证
内容提供者

该用户很懒,什么也没介绍

版权声明书
用户编号:8000054077000003

1亿VIP精品文档

相关文档