北航14春《建筑结构检测鉴定与加固》在线作业三(国外英语资料)
北航14春《建筑结构检测鉴定与加固》在线作业三(国外英语资料)
The northern building structure detection and reinforcement of online homework three
Total score: 100 test time: - test scores: 100
First, radio questions (10 questions, 40 points) Score: 40
1. as long as the calculation of the shear capacity formula and configuration of stirrups within the beam, then ().
A. certainly does not occur shear failure
B. inclined crack width can meet the requirement
C. does not happen longitudinal reinforcement anchorage failure
D. only occurs flexural failure
Answer: A
Full Score: 4 points: 4
2. the building damage assessment rating method divides the building into () class
A. 2
B. 3
C. 4
D. 5
Answer: C
Full Score: 4 points: 4
3. in the reinforced concrete column construction, the load of the original column should be controlled at the ultimate bearing capacity.
A. 40%
B. 50%
C. 60%
D. 70%
Answer: C
Full Score: 4 points: 4
The evaluation grade of 4. () is whether the structural components can meet the requirements of the individual functional requirements (reliability requirements).
A. project
B. unit
C. subkey
D. combination project
Answer: C
Full Score: 4 points: 4
5. the correct and reasonable design of space between the expansion joints in the same area shall be considered as follows: (1) which of the following is true?
A. retaining walls and basement wall structures are protected from soil and the spacing of expansion joints is larger than other structures
Because of its poor integrity, the B. fabricated structure should be smaller than the cast-in-place structure
The C. shear wall structure has large rigidity, comparable expansion joint spacing and large frame bent structure
The D. bent structure column is less than 8 meters high. The construction of shear wall structure with sliding formwork should reduce the spacing of expansion joint
Answer: D
Full Score: 4 points: 4
6. when the target reliability index of concrete structure is 3.7 (brittle failure) and 3.2 (ductile failure), the safety grade of