DCS要求一点接地(国外英语资料)
DCS要求一点接地
DCS asked for a little grounding..txt, Ive only had two things in my life. No, that wont be, and neither will. Others have backgrounds, and I have back figures. The ideal of meat, the fate of cabbage. The ideal of meat, the fate of cabbage. White horse. Where have you been?! Did you lose the prince and dare not come to see me?. --------------------------------------------------------------------------------
DCS requires one point grounding, but the relay requires two points on the ground, and when the amount of electrical appliances enters the DCS, there are two kinds of conflicts. My personal opinion should be done in accordance with the provisions of DCS. Please discuss it
--------------------------------------------------------------------------------
Agree with this opinion, because the current relay protection is separate, transformation of electrical quantities is also limited to monitoring, integrated substation automation microcomputer system grounding and DCS system, so only considered by DCS system grounding.
--------------------------------------------------------------------------------
Article 14.0.16 of the code for design of relay protection and automation device of electric power equipment (GB50062-92) stipulates that when static protection is adopted, shielded cables shall be adopted, and the shielding layer shall be grounded at both ends. This is not in accordance with the grounding of the shielding layer specified by the thermal automation specialty.
In theory, the shielding layer grounding point (note, here referred to multi-point grounding is the grounding grid, and the non local nature), the shielding layer is completely equipotential, interference will be reduced to the minimum, but cannot do so, appropriate electrical back ends ground. Because static protection of field devices is relatively centralized, this is also easy to implement. Thermal automation to do a little grounding requirements, the following considerations:
1, the the