谁能回答变频器的问题(国外英语资料)
谁能回答变频器的问题
Chapter 1 main circuit of frequency converter
1., why is the unit of rated capacity of motor kW, while the unit of rated capacity of frequency converter is kVA?
2. why inverter bridge must adopt power transistor?
3. what is the main circuit of an AC DC cycloconverter?
4. what is the allowable range of the input voltage of the inverter, 340~420V, and what is the range of the DC average voltage?
Whats the effect of the 5. current limiting resistor? Burned out how to match?
Whats the function of the 6. voltage resistance? What is the possible cause of the burn out of a constant voltage resistor?
7. what is the function of the DC power indicator?
Why is the diode 8. parallel to the reverse diode?
9. when the motor is running at 50Hz, the current is 80A, and the input current of the converter is close to 80A. If the motor is running at 20Hz, the current is still 80A. What is the input current of the inverter?
10. when the output voltage of the converter is equal to 150V, 250V and 380V, what is their pulse height?
11. to determine whether the inverter is overloaded, which part of the current should be measured? Which part of the current should be measured when measuring the electrical energy consumed by the frequency conversion drive system?
12. why does the parallel compensation capacitor in the input side of the inverter not change the power factor?
13. in frequency conversion timing system, what is the influence of the power factor of the motor on the input side of the inverter?
14. what parts of the converter may be a source of interference to other equipment during operation?
15. a constant pressure water supply system, the frequency converter running, the flowmeter can not work properly, what measures can be taken to solve?
The second chapter is the load characteristic of the motor after frequency conversion
1. inverter in the inverter at the same time, why have to change the pressure?
2. why is the motor torque lifting in low frequency?
3. what is the co
您可能关注的文档
最近下载
- JBT 5088.1-2018 内燃机 旋装式机油滤清器 第1部分:技术条件.pdf VIP
- 英语丨贵州省贵阳市2024届高三上学期8月摸底考试英语试卷及答案.pdf VIP
- QJ700-8A(钱江追700)维修手册.pdf VIP
- QJ400GS-16D钱江(赛450)维修手册.pdf VIP
- 体例格式12:任务3教学单元5工学一体化课程《windows服务器基础配置与局域网组建》之教学单元活动方案.docx VIP
- Pride and Prejudice-傲慢与偏见-中英对照剧本.pdf VIP
- 铁附件金具重量表.docx VIP
- 数学建模国赛2020C.pdf VIP
- T_SLDA 019-2025 全光谱吸顶灯技术规范.docx
- 2025年中央经济工作会议全文PPT.docx VIP
文档评论(0)