电梯常见故障及维修(国外英语资料)
电梯常见故障及维修(国外英语资料)
Common fault and handling methods of elevator
Common fault and handling methods of elevator
Along with the rising number of the elevator, the elevator maintenance and troubleshooting has become the main task of the elevator maintenance personnel daily work, and to this end, we are on the basis of practical experience summed up some of the common faults and processing methods, hoping to be helpful to the personnel engaged in the elevator maintenance.
The first part of the elevator has a common fault and treatment method for the gear towing mechanism
A towed motor is short-circuited to the ground
The phenomenon of
The current surges, the power supply switch fuse or automatic jump button, the control line is off power. The temperature of the motor has risen sharply, much higher than the nameplate. Winding insulation resistance of the motor shell is zero (if the motor for the single winding YY/Y connection, 6 outlet terminals on the casing resistance are all zero, Y/Y connection, double winding motor three outlet terminals on the casing resistance is zero). The contact area is in the lower end of the motor winding.
why
The winding itself has a wound, such as the wiring and slot wedge. The use of daily insulation strength decreases, causing local electric breakdown. Room 2. Motor oil leak, impregnated winding, moisture in the oil and dirt will reduce the winding insulation level, over time will fever caused by the leakage, finally lead to breakdown. The elevator is constantly braking (starting current is 3 ~ 4 times that of the rated current), the motor is in high temperature in the long run, the insulation is premature aging and it is punctured.
Prevention and treatment
1. Before using the 500 v motor insulation shaking table test, insulation resistance in more than 0.5 M Ω. When maintaining, keep the winding especially in the lower part of the body, and often use a leather tiger to blow away dust and debris. 3. Avoid the spill oil chamber, ensure the