热电偶与热电阻的区别(The difference between thermocouple and thermal resistance)

热电偶与热电阻的区别(The difference between thermocouple and thermal resistance) One, the difference: 1. Although is non-contact thermometer table, but their different temperature range, thermocouple used in high temperature environment, such as platinum rhodium 30 - platinum rhodium 6 (B) measuring range is 300 ~ 1600 degrees, 1800 degrees short-term measurable. The s-type measurement is one 20 ~ ~ 1300 (short-term 1600), the K type measuring one 50 ~ ~ 1000,? (short-term 1200). The XK type is 50 ~ ~ 600 (800), and the E type is 40 ~ ~ 800 (900). Theres the J, the T, and so on. This type of meter is generally used in high temperature over 500 degrees, because they are in the low temperature zone thermoelectric potential output is small (we can have a look at the table), when the potential hours, against interference measures and the second table and requirement is high, otherwise the measurement, and, in the region of the low temperature, the change of the cold end temperature and the relative error caused by the change of environmental temperature is very outstanding, is not easy to get full compensation. At the middle and low temperature, the temperature range of thermal resistance is a range of 200 ~ ~ 500, and even lower temperature can be measured (such as using carbon resistance to measure the low temperature of 1K). Now normal use Pt100 platinum thermal resistance, (also have Pt50, 100 and 50 representative at 0 degrees of resistance, thermal resistor in the old index number with BA1, BA2, BA1 at 0 degrees for 46 ohm resistance value, useful also copper resistance in the industry, index number is CU50 and CU100, but small temperature range, between the 50 ~ 150. In some special occasions and indium resistance, manganese resistance? Etc.)? 2. The basic principle of thermocouple measurement is thermoelectric effect. The second table is a voltmeter or an electronic potentiometer to improve the accuracy. Resistance is based on the properties of conductors and semiconducto

文档评论(0)

jgx3536 + 关注
实名认证
内容提供者

该用户很懒,什么也没介绍

版权声明书
用户编号:6111134150000003

1亿VIP精品文档

相关文档