DOI:10.13334/j.0258-8013.pcsee.2013.08.006
33 8 Vol.33 No.8 Mar.15, 2013
2013 3 15 Proceedings of the CSEE ©2013 Chin.Soc.for Elec.Eng. 1
0258-8013 (2013) 08-0001-08 TK 264 A 470 20
( 071003)
Thermodynamic Analysis of Heat Pump Heating Supply Systems With
Circulating Water Heat Recovery
ZHANG Xuelei, CHEN Haiping
(School of Energy, Power and Mechanical Engineering, North China Electric Power University,
Baoding 071003, Hebei Province, China)
ABSTRACT: Heat recovery from circulating water based on
absorption heat pump can achieve the energy cascade 1.706
utilization. Take a certain 300MW regulated extraction steam 11.17 4.63MW
turbine as an example, this paper studied the feasibility of heat
pump heating supply system (HPHSS) with circulating water
heat recovery. The thermodynamic model, which considered
the influence of heat recovery on condenser vacuum, was
proposed to simulate the HPHSS design and off-design
performance from the perspective of the overall system. The
results indicate that at design condition, the heat pump
coefficient of performance (COP) is 1.706, and HPHSS
increases exergy efficient by 11.17 percentage points and