楼板,梁钢筋的要求(Requirements for floor and beam reinforcement).doc

楼板,梁钢筋的要求(Requirements for floor and beam reinforcement).doc

  1. 1、本文档共9页,可阅读全部内容。
  2. 2、原创力文档(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。
  3. 3、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载
  4. 4、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
查看更多
楼板,梁钢筋的要求(Requirements for floor and beam reinforcement)

楼板,梁钢筋的要求(Requirements for floor and beam reinforcement) Dark column content: 1.1 columns of steel on the root of the cement has been cleaned. 1.2, in order to ensure the location of the main column of the concealed column is accurate, the fixed distance frame control is adopted Binding of 1.3 columns of steel bars: The number of 1.3.1 column stirrups is determined according to the requirements of the drawing. The first stirrup is set at the end of the 50mm. 1.3.2 draw the stirrup line on the vertical bar, and then tie it up and down from the top to the bottom. 1.3.3 the joints of the stirrups shall be arranged along the vertical bars of the column. The stirrups shall be perpendicular to the vertical bars and the buckle shall be headed inward. 1.3.4 dark column stirrups and wall banding requirements: dark column stirrups and wall horizontal reinforcement staggered 20mm above, shall not be together. Wall, concealed column, connection beam, steel bar: 2.1, the root of the wall reinforcement slurry has been cleaned. 2.2 wall reinforcement has been adjusted. Ascended the throne to move too big request to adjust according to 1:6, the first grade steel bars curved hook is all facing inside, not vertical straightening. 2.3 starting tendon requirements: 2.3.1 the distance between the first wall and the column edge at the edge of the dark column is 50mm. 2.3.2 wall, the first wall bar is 50mm from the concrete slab. 2.3.3 dark column, the first stirrup is 30mm from the concrete slab. 2.3.4 connecting beam from the side of the column, 50mm. 2.3.5 coupling beams, such as columns, a hoop, 50mm. Requirements for vertical reinforcement of wall: 2.4.1 lap length shall be no less than 45d, and three horizontal bars shall be guaranteed at the lap joint. The binding range shall be no less than three buckles. The vertical rib of the wall is staggered by 50%, and the stagger distance is not less than 1.3 times of the overlap length between the adjacent joints. 2.4.2 horizontal reinforc

文档评论(0)

jgx3536 + 关注
实名认证
内容提供者

该用户很懒,什么也没介绍

版权声明书
用户编号:6111134150000003

1亿VIP精品文档

相关文档