长城电源维修关键测试点(Great Wall power supply maintenance key test point).docVIP

  • 31
  • 0
  • 约1.86万字
  • 约 18页
  • 2017-08-03 发布于河南
  • 举报

长城电源维修关键测试点(Great Wall power supply maintenance key test point).doc

长城电源维修关键测试点(Great Wall power supply maintenance key test point) Great Wall power supply maintenance key test point   1, KA7500B feet (power supply foot) : 12 normal data: + 12 v + 20 v or so, a few machines 26 v is normal.     2, LM339N 3 feet (foot) PG output: normal data: 5 v     3, KA7500B 8, and 11 feet (half bridge driver output) : normal data: + 2 v or so     4, KA7500B foot protection (foot) 4: normal data: 0 v, such as 3 v, the circuit in the protection state.     5, KA7500B 13, 14, 15 feet internal output pin (IC) : internal output 5 v.   Great Wall series power su