西交《发电厂电气部分(高起专)》在线作业(West to power plant electrical parts (higher) online operation)
West to power plant electrical parts (higher) online operation
Total score: 100 test time: -
Radio examination
A multiple-choice question
Judgment question
Radio examination questions (20 questions, 40 points)
1. the shape factor Kf in the formula of three-phase electrodynamic force is determined by ()
Mechanical strength of A. conductors
The shape of a B. conductor
Layout position of C. conductor
Shape and relative position of D. conductor
Full marks: 2
2., the choice of distribution equipment, usually to determine the technical and economic comparison, the general () voltage level should be used inside the power distribution device.
A., 35kV and below
B., 35kV and above
C., 10kV and above
D., 110kV and below
Full marks: 2
3. in power system, shunt reactor is mainly used ()
A. limits short-circuit current at fault
Capacitive reactive power in B. absorbing power grid
C. provides capacitive reactive power to the system
Full marks: 2
4. thermal power plant using the generator transformer unit, auxiliary working power generator by connecting with the factory, branch line adopts isolated phase enclosed bus, a branch line should be the correct equipment or other facilities described in ()
A. shall be equipped with circuit breakers
The B. shall be provided with disconnecting switches and shall not be fitted with circuit breakers
C. shall be equipped with removable points
The D. shall not be equipped with any equipment or facilities
Full marks: 2
5. three-phase three column voltage transformers can be used to measure ()
A. line voltage
B. phase voltage
C. zero sequence voltage
D. negative sequence voltage
Full marks: 2
6. the phase operation of the generator will lead to ()
A. static stability reduction
B. static stability improved
C. had no effect
D. is not sure
Full marks: 2
The 7. () connection will interrupt the circuit power supply when the outlet breaker is checked and repaired.
A. s
您可能关注的文档
- 中国高速铁路建设规划(China's high-speed railway construction plan).doc
- 中国风纯音乐(Chinese wind pure music).doc
- 中国高速铁路建设规划1(China high-speed railway construction plan 1).doc
- 中国行政管理史 论文(Chinese administration history paper).doc
- 中巴建能源走廊(China-pakistan energy corridor).doc
- 中国酒商之变(The change of Chinese wine merchants).doc
- 中国科学院院士籍贯地市排行榜(Academician of Chinese academy of sciences).doc
- 中国联通广州营业厅(China unicom guangzhou office).doc
- 中国美术史答案(Answer to Chinese art history).doc
- 中国民族民间舞等级考级教材(Chinese folk dance grade examination textbook).doc
- GB/T 14598.2-2025量度继电器和保护装置 第1部分:通用要求.pdf
- 中国国家标准 GB/T 14598.2-2025量度继电器和保护装置 第1部分:通用要求.pdf
- 《GB/T 14598.2-2025量度继电器和保护装置 第1部分:通用要求》.pdf
- 《GB/T 14598.26-2025量度继电器和保护装置 第26部分:电磁兼容要求》.pdf
- GB/T 14598.26-2025量度继电器和保护装置 第26部分:电磁兼容要求.pdf
- 中国国家标准 GB/T 14598.26-2025量度继电器和保护装置 第26部分:电磁兼容要求.pdf
- 《GB/T 19024-2025质量管理体系 面向质量结果的组织管理 实现财务和经济效益的指南》.pdf
- 中国国家标准 GB/T 19024-2025质量管理体系 面向质量结果的组织管理 实现财务和经济效益的指南.pdf
- GB/T 19024-2025质量管理体系 面向质量结果的组织管理 实现财务和经济效益的指南.pdf
- 中国国家标准 GB/T 20441.8-2025电声学 测量传声器 第8部分:测定工作标准传声器自由场灵敏度的比较法.pdf
文档评论(0)