结构设计与审查常见问题(Common issues in structural design and review).docVIP

结构设计与审查常见问题(Common issues in structural design and review).doc

  1. 1、本文档共15页,可阅读全部内容。
  2. 2、原创力文档(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。
  3. 3、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载
  4. 4、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
  5. 5、该文档为VIP文档,如果想要下载,成为VIP会员后,下载免费。
  6. 6、成为VIP后,下载本文档将扣除1次下载权益。下载后,不支持退款、换文档。如有疑问请联系我们
  7. 7、成为VIP后,您将拥有八大权益,权益包括:VIP文档下载权益、阅读免打扰、文档格式转换、高级专利检索、专属身份标志、高级客服、多端互通、版权登记。
  8. 8、VIP文档为合作方或网友上传,每下载1次, 网站将根据用户上传文档的质量评分、类型等,对文档贡献者给予高额补贴、流量扶持。如果你也想贡献VIP文档。上传文档
查看更多
结构设计与审查常见问题(Common issues in structural design and review) Some common problems of standard serial number processinspection agency comments Specification number entry A load and calculation part 1 Calculation of unidirectional seismic action, without considering the impact of occasional eccentricity. JGJ3-2002 3.3.3 rectification 2 for important or very sensitive to wind load of high-rise building the basic wind pressure according to the 100 year return period wind pressure value is used. JGJ3-2002 3.2.2 rectification 3 high-rise building fire evacuation stairs, load value is less than 3.5kn/m2. GB50009-2001 4.1.1 rectification 4 people on the roof live load are still using the old standard value of 1.5 kn/m2, the people on the roof should be non building professional confirmation, sometimes according to the design of roof structure non for roofs on buildings. GB50009-2001 4.3.1 rectification 5 of hotels, hospitals and other local toilet partition layout is dense, not converted into equivalent load according to the actual input, such as the wall weight per meter 1/3 reduced survival load value is too small, and more than 1 kn/m2. GB50009-2001 4.1.1 note 5 rectification 6 of the irregular plane structure, the first torsion vibration cycle pressure Tt and translational dominated the first period T1 ratio structure, A-class height more than 0.9 B, height is greater than 0.85. JGJ3-2002 4.3.5 rectification 7 of the mass and stiffness distribution is obvious asymmetry, uneven structure is calculated according to unidirectional horizontal earthquake. JGJ3-2002 3.3.2 rectification 8 of V shape, Y shape, curved, well shaped flat building, wind load shape coefficient is 1.3. JGJ3-2002 3.2.5 comments 9 cast-in-place floor in the stiffness of the beam increases the coefficient of 1, causes the beam reinforcement bearing small. JGJ3-2002 5.2.2 comments 10 degree 7-9, frame structure without weak layer test and checking GB50011-2001 5.5.2 audit opinion 11 underground building an

您可能关注的文档

文档评论(0)

f8r9t5c + 关注
实名认证
文档贡献者

该用户很懒,什么也没介绍

版权声明书
用户编号:8000054077000003

1亿VIP精品文档

相关文档