电气设备的保养规程(Maintenance regulations for electrical equipment)
Maintenance procedures for electrical equipment
In the operation of transformer outage or annual maintenance time, stop the transformer increase maintenance time before being put into use.
Maintenance procedures:
(1) maintenance to disconnect the transformer low voltage side of the circuit breaker, isolating switch, pull down, hanging signs corresponding on the handle.
(2) disconnect the load switch transformer high voltage side, confirmed in the open position after the grounding knife switch, and complete the safety insurance and hung signs.
(3) oil into the transformer room, first confirm the transformer is in the state power application of high voltage electroscope, and pull the high-voltage isolation knife, and then check the shell, insulator and lead without deformation, damage should be replaced, the oil level is normal, if there is oil leakage phenomenon, should replace the pad, check whether silicone if effective, discoloration or serious failure, should be replaced immediately.
(4) re fastening lead terminal, pin, grounding screw; screw into the line, such as loose, remove the screw with a thin flat file file light touch interface, without any uneven feel with the hand, with a clean cloth to wipe the dust, wipe Vaseline, replaced with new spring washers fastening screw.
(5) check the surrounding dust removal equipment transformer lighting, heat dissipation, is intact, and the dust on the transformer body and porcelain with a clean cloth wipe.
(6) check the high voltage side of the transformer load switch, ensure the flexible operation, good contact, transmission part lubrication.
(7) 2500V tramegger measuring transformer high voltage coil insulation resistance (phase to ground and meet the requirements, confirm) at room temperature (30 DEG C, the transformer high voltage side 1OKV greater than 20M, the low pressure side of greater than 13M. Before the test, have good grounding wire, determined afte
您可能关注的文档
- 精怪班主任 和调皮鬼过招让90后、00后学生心悦诚服(Demon teacher and mischievous ghost blows to the 90, 00 after convincing students).doc
- 精加工新技术(Fine machining new technology).doc
- 精馏塔开停车步骤(Rectification tower opening and stopping steps).doc
- 精美摘抄,献给每一位有理想的大学生(Exquisite excerpt, for every ideal college).doc
- 精密空调与普通家用空调区别(The difference between precision air conditioner and ordinary home air conditioner).doc
- 精明主妇教你省钱妙招(A smart housewife teaches you how to save money).doc
- 经济顶层设计三核心(Economic top-level design three core).doc
- 精养鱼池的水质与调控技术(Water quality and regulation techniques of fishpond).doc
- 精益生产管理(Lean production management).doc
- 竞技钓比赛规则(2)(Rules of competitive fishing (2)).doc
文档评论(0)