框架结构设计技术措施(Frame; structural design; technical measures) Frame; structural design; technical measures In the structure design of different types of some of the content is the same, such as floors, stairs, this article is intended to help the designer in the design of the frame structure. This paper can reduce the leakage, reduce errors, and the same content of the reader can skip. The details are as follows: 1. structural design notes Design is mainly based on seismic grade, air defense level, and the bearing capacity of the foundation, moisture impermeability practice, the value of live load, material grade, matters needing attention in the construction with details, general details or nodes, as well as in the construction not shown in the figure to express through that information. Such as the concrete alkali content shall not exceed 3kg/m3. 2. the structural layout of each floor, including: (1). The precast slab layout (plate selection, slab size and reinforcement). Mark number and type of the precast slab, do not use diagonal form. Because this method is easy to cause the crossing of the line, the horizontal or vertical lines should be adopted, and the type of room should be marked directly with the same type of room. Should be unified number of the whole floor, can reduce the design workload, but also facilitate the construction staff to look at. As far as the seam 40, the seam unworthy of the muscle or with a rib. The room layout from the inside out, as far as possible the use of wide plate slab with in the window, the best bandwidth of more than 200 cast-in-place slab (considering the riser wear plate plumbing). If the entire water layer construction requirements, seams should be greater than 60. The overall casting thickness is 50, with two-way phi 6@250, concrete C20. Generally, the pure frame structure does not need the whole casting layer. Prefabricated slabs shall not be allowed at constructional poles. The underground garage can not be prefabricated due

文档评论(0)

f8r9t5c + 关注
实名认证
文档贡献者

该用户很懒,什么也没介绍

版权声明书
用户编号:8000054077000003

1亿VIP精品文档

相关文档