- 1、本文档共3页,可阅读全部内容。
- 2、原创力文档(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。
- 3、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载。
- 4、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
查看更多
框架结构设计技术措施(Frame; structural design; technical measures)
Frame; structural design; technical measures
In the structure design of different types of some of the content is the same, such as floors, stairs, this article is intended to help the designer in the design of the frame structure. This paper can reduce the leakage, reduce errors, and the same content of the reader can skip.
The details are as follows:
1. structural design notes
Design is mainly based on seismic grade, air defense level, and the bearing capacity of the foundation, moisture impermeability practice, the value of live load, material grade, matters needing attention in the construction with details, general details or nodes, as well as in the construction not shown in the figure to express through that information. Such as the concrete alkali content shall not exceed 3kg/m3.
2. the structural layout of each floor, including:
(1). The precast slab layout (plate selection, slab size and reinforcement). Mark number and type of the precast slab, do not use diagonal form. Because this method is easy to cause the crossing of the line, the horizontal or vertical lines should be adopted, and the type of room should be marked directly with the same type of room. Should be unified number of the whole floor, can reduce the design workload, but also facilitate the construction staff to look at. As far as the seam 40, the seam unworthy of the muscle or with a rib. The room layout from the inside out, as far as possible the use of wide plate slab with in the window, the best bandwidth of more than 200 cast-in-place slab (considering the riser wear plate plumbing). If the entire water layer construction requirements, seams should be greater than 60. The overall casting thickness is 50, with two-way phi 6@250, concrete C20. Generally, the pure frame structure does not need the whole casting layer. Prefabricated slabs shall not be allowed at constructional poles. The underground garage can not be prefabricated due
您可能关注的文档
- 柏松素前花青素的保健效果(Bai Songsu proanthocyanidines health effects).doc
- 案例及分析 无领导小组(Case and analysis leaderless group).doc
- 成语谜语大全(A complete set of idioms and riddles).doc
- 板梁结构随机振动(psd)分析(Random vibration (PSD) analysis of plate girder structures).doc
- 成长的烦恼每集名称简介(Growing pains, each episode, name, introduction).doc
- 板木支撑计算(Calculation of plate and wood support).doc
- 板式楼梯梯板厚度确定(Gangboard stair slab thickness determination).doc
- 成长历程作文(Growing up composition).doc
- 板式散热器的优缺点(Advantages and disadvantages of plate type radiator).doc
- 棒材和线材的区分(Distinction between bar and wire).doc
最近下载
- 贵州省贵阳市白云区2025年初中毕业生学业水平模拟试卷(二)语文试题(含答案).docx VIP
- 企业文化建设与落地实践.pptx VIP
- (2025修订版)CAAC无人机理论考试题库(含答案).docx
- 光电化学课件-电化学研究方法-第一讲-电化学热力学.pdf VIP
- 《不抱怨的世界》读书分享课件PPT课件.pptx
- PEP人教版小学英语三年级下册unit3 At the zoo A Let‘s learn 教案.pdf VIP
- 《AI人工智能咖啡系统》.pdf VIP
- 《第八课 身体红绿灯》参考课件.pptx VIP
- 《安乐死与伦理》课件.ppt VIP
- 2025年部编版语文四年级下册全册教案(简案).pdf VIP
文档评论(0)