发电机定子绕组端部动态特性试验的实践体会 practise and experience on dynamic response test of generator stator winding ends.pdfVIP

  • 7
  • 0
  • 约8.04千字
  • 约 3页
  • 2017-08-13 发布于上海
  • 举报

发电机定子绕组端部动态特性试验的实践体会 practise and experience on dynamic response test of generator stator winding ends.pdf

发电机定子绕组端部动态特性试验的实践体会 practise and experience on dynamic response test of generator stator winding ends

No. 3 2007 华北电力技术 NORTH CHINA ELECTRIC POWER 15 发电机定子绕组端部动态特性试验的实践体会 任澄涛,田东明 (大唐国际北京高井热电厂,北京 10004 1) 摘 要:在高井热电厂电气试验的实践基础上,介绍发电机定子绕组端部动态特性试验在生产中的重要作用, 并讨论对相关标准的掌握和运用问题。 关键词:发电机;定子绕组;端部;动态特性 中图分类号: TM621. 5 文献标识码:B 文章编号:1003-917 1(2007 )03-0015-03 Practise and Experience on Dynamic Response Test of Generator Stator Winding Ends Ren Cheng-tao ,Tian Dong-ming (Datang International Beijing Gaojing Cogeneration Power Plant ,Beijing 10004 1,China ) Abstract :Based on the practise of electric tests in Gaojing Thermal Power Plant ,this paper introduces the important part that the dynamic response tests of generator winding ends have been playing in production ,and discusses several problems to judge and apply reletive standards. Key words :generators ;stator winding ;ends ;dynamic response 国家电力公司2000 年9 月发布的《防止电力 变电磁场的作用,定子铁芯也存在50 Hz 的铁磁 生产重大事故的二十五项重点要求》中第 11. 1 性振动;另一种是由转子磁场在定子铁芯和定子 条强调,为防止发电机定子绕组端部松动引起相 绕组线棒上引起的倍频(100 Hz )振动,绕组上受 间短路,应经常检查定子绕组端部线圈的磨损和 到的振动力与电流的平方成正比,故容量大的发 紧固情况,对200 MW 及以上的发电机在大修时 电机中交变电磁力更大。设计合理并且制造工艺 应做定子绕组端部振型模态试验,发现问题应采 良好的发电机,应当能够使这两种频率的振动幅 取针对性措施。同时,现行的发电机交接及预防 值限制在规定范围内,长期连续运行而不会影响 性试验规程中都规定了发电机定子绕组端部引线 发电机的寿命。大量的事故统计分析表明,发电 自振频率的试验要求。下面根据高井热电厂电气 机定子绕组端部是发电机安全运行的薄弱部位。 试验的实践经验谈谈发电机定子绕组端部动态特 由于定子绕组端部类似悬臂梁结构,难以像槽中 性试验的在生产中的重要作用、相关标准的掌握 线棒那样被牢固固定。因此,较易受到电磁力的 和运用等问题。 破坏。当发电机存在设计和制造质量隐患时,有 可能在运行一段时间后发生端部紧固结构的松 1 发电机定子绕组端部动态试验在生产 动,进而使线棒绝缘磨损,若不及时处理,最终将 中的作用 发展成灾难性的相间或对地短路事故。因为定子 1. 1 发电机定子绕组端部运行时

您可能关注的文档

文档评论(0)

1亿VIP精品文档

相关文档