2 高压设备工作的基本要求(2 basic requirements for high voltage equipment).docVIP

2 高压设备工作的基本要求(2 basic requirements for high voltage equipment).doc

  1. 1、原创力文档(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。。
  2. 2、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载
  3. 3、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
  4. 4、该文档为VIP文档,如果想要下载,成为VIP会员后,下载免费。
  5. 5、成为VIP后,下载本文档将扣除1次下载权益。下载后,不支持退款、换文档。如有疑问请联系我们
  6. 6、成为VIP后,您将拥有八大权益,权益包括:VIP文档下载权益、阅读免打扰、文档格式转换、高级专利检索、专属身份标志、高级客服、多端互通、版权登记。
  7. 7、VIP文档为合作方或网友上传,每下载1次, 网站将根据用户上传文档的质量评分、类型等,对文档贡献者给予高额补贴、流量扶持。如果你也想贡献VIP文档。上传文档
查看更多
2 高压设备工作的基本要求(2 basic requirements for high voltage equipment)

2 高压设备工作的基本要求(2 basic requirements for high voltage equipment) 2 basic requirements for high voltage equipment work ********2.1 general safety requirements. 2.1.1 operation personnel should be familiar with the electrical equipment. Separate personnel on duty or operation of the responsible person on duty should also have practical work experience. 2.1.2 high voltage equipment in accordance with the following conditions, can be a single or single operator on duty: 1) isolation room indoor high voltage equipment with barriers, barriers height above 1.7m, firmly installed and locked them. 2) indoor high voltage circuit breaker (switch) actuator (operating mechanism) with a wall or a metal plate and the circuit breaker (switch) or a remote isolation actuator (operating mechanism). The 2.1.3 converter does not allow single duty or single operation. 2.1.4 no matter whether the high-voltage equipment is charged, the staff may not remove or across the barriers to work; if it is necessary to remove the barriers, and in accordance with the table should be guardian present, the safe distance of 2-1. Result table 2-1 equipment when power failure safety distance The voltage level (kV) safety distance (m) voltage (kV) safety distance (m) 10 and below (13.8) 0.70 m 7507.20 M 20, 351, 1 m 8.70 63 (66), 110 1.50M + 50 and 1.50M 220 3.00m + 500 6.00m 330 4.00m + 660 8.40m 5005 m + 800 9.30m Table is not listed in the voltage according to the voltage level of a high safety distance. The 750kV data is by elevation of 2000m correction, the other level of data correction according to elevation 1000m. 2.1.5 10, 20, 35kV (in) outdoor distribution equipment across the exposed part of the pedestrian or the working area, if part of the conductive height were less than 2.7 (2.5), 2.8 (2.5), 2.9m (2.6m), the exposed part of the sides and the bottom should be installed with a protective net. The traffic channel 2.1.6 outdoor lOkV and above high voltage distribution device in place, should be

您可能关注的文档

文档评论(0)

f8r9t5c + 关注
实名认证
文档贡献者

该用户很懒,什么也没介绍

版权声明书
用户编号:8000054077000003

1亿VIP精品文档

相关文档