网站大量收购独家精品文档,联系QQ:2885784924

pkpm系列新规范应用指南——短肢剪力墙_祝耀林(PKPM series of new standard application guide - short shear wall _ Zhu Yaolin).doc

pkpm系列新规范应用指南——短肢剪力墙_祝耀林(PKPM series of new standard application guide - short shear wall _ Zhu Yaolin).doc

  1. 1、本文档共5页,可阅读全部内容。
  2. 2、原创力文档(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。
  3. 3、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载
  4. 4、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
查看更多
pkpm系列新规范应用指南——短肢剪力墙_祝耀林(PKPM series of new standard application guide - short shear wall _ Zhu Yaolin)

pkpm系列新规范应用指南——短肢剪力墙_祝耀林(PKPM series of new standard application guide - short shear wall _ Zhu Yaolin) Guide for the application of PKPM series of new specification of short pier shear wall _ to Yaolin Baidu space | Baidu home page | Yaolin Yaolin blog homepage to login to the album | personal files | friends see article PKPM series new specifications Application Guide -- short leg shear wall 2008-07-03 19:33 specification: The 7.1.2 stipulates that the structure of high-rise buildings should not adopt all short leg shear walls. The short leg shear wall should be arranged as a cylinder (or a general shear wall) for a long time to form a shear wall structure with short pier shear wall and cylinder resisting the horizontal force, and comply with the following provisions: 1. maximum use height should be lower than table 4.2.2-1, 7, 8 degrees of seismic design, chalk should not be greater than 100m and 60m. In 2. seismic design, the seismic overturning moment at the bottom of the first vibration mode of the cylinder and the general shear wall should be no less than 50% of the total overturning moment of the total bottom of the structure. In 3. seismic design, the seismic grade of short limb shear wall is higher than that of shear wall established by table 4.8.2. 4. in seismic design, the axial compression ratio of the short pier shear wall is 1, 2 and 3 respectively, and should be no more than 0.5, 0.6, 0.7; the short pier shear wall with no flange or end column, the axial compression ratio limit is correspondingly reduced by 0.1. 5. seismic design, in addition to the bottom strengthening parts according to the high gauge 7.2.10 adjustment shear design, the other layers of short leg shear wall design value, 1, 2, respectively, multiplied by the amplification factor 1.4 and 1.2. 6., seismic design, short shear wall section of all longitudinal reinforcement ratio, the bottom reinforcement parts should be less than 1.2%, other parts should be less than 1%. 7. the thicknes

文档评论(0)

jgx3536 + 关注
实名认证
内容提供者

该用户很懒,什么也没介绍

版权声明书
用户编号:6111134150000003

1亿VIP精品文档

相关文档