电机故障处理(Motor fault treatment)

电机故障处理(Motor fault treatment) Application of three-phase asynchronous motor widely, but through a long time after the operation, there are different kinds of fault, timely judge fault reason, processed, is to prevent the expansion of the fault, which is an important work of the normal operation of equipment. ? First, the electric motor can not rotate, but it is no noise, no smell and smoke. 1.. The cause of the failure is that the power supply is not connected (at least two phases are not connected); fuse fusing (at least two phases fusing); overcurrent relay is too small; and the control equipment is wired wrong. ??? 2. troubleshooting 1 check the power supply circuit switch, fuse wiring box, whether there is a breakpoint, repair; check the fuse type, fuse, fuse and change; relay setting and motor coordination; the correct wiring. ? two, after the power, the motor does not turn, and then fuse to burn ??? 1. fault reason for lack of one phase power supply, or a dry coil instead; the stator winding short circuit; the stator windings of the stator winding grounding; wrong wiring; the fuse section is too small; the power line short circuit or grounding. ??? 2. troubleshooting check switch if a phase is not closed, a power supply circuit can eliminate phase disconnection; reverse fault; the detected short-circuit point to be repaired; the elimination of grounding; the detected misconnection and corrected; the replacement of the fuse; eliminate the ground. ? three, after the power, the motor does not turn, there is a buzz ??? the reasons for L. failure of stator and rotor winding circuit (a phase disconnection) or a loss of power supply phase; the winding line was wrong or at the end of windings reversed; the power supply circuit of loose contact, the contact resistance is large; the motor load is too large or the rotor stuck; the power supply voltage is too low; the small motor assembly is too tight or grease in bearing and bearing stuck excellent. ??? 2. troubleshootin

您可能关注的文档

文档评论(0)

f8r9t5c + 关注
实名认证
文档贡献者

该用户很懒,什么也没介绍

版权声明书
用户编号:8000054077000003

1亿VIP精品文档

相关文档