analysis of the distribution network neutral point grounding mode and select(分析配电网中性点接地方式和选择)

Analysis of the distribution network neutral point grounding mode and select To write papers network: Abstract: the power system neutral grounding method is a comprehensive technical subjects involving many aspects of power system, which involves not only the safety and reliability of the grid itself, over the choice of the voltage insulation level, and interfere with communication personal safety. Thesis Keywords: distribution network, the neutral point A neutral point grounding mode (A neutral point ungrounded distribution network neutral point grounding method, the neutral point-to-ground insulation, simple structure, convenient operation, without any additional equipment investment, applicable to the rural 10kV overhead line radiation shaped or tree-shaped power supply network of the ground the way in running the event of a single phase to ground fault current flowing through the point of failure is only the grid-to-ground capacitance current, its value is very small, need the installation of insulation monitoring device In order to detect single-phase ground fault, to be dealt with promptly to avoid failure the development of two-phase short-circuit caused the blackout. Neutral point ungrounded system single-phase ground fault occurs, the ground current is very small, if the instantaneous failure is generally automatic arc non-fault phase voltage rise is not and will not destroy the symmetry of the system, with fault continuous supply 2h to obtain troubleshooting time and improve reliability of power supply. (Two neutral traditional arc suppression coil grounding the neutral point by the arc suppression coil grounding method, that is, between the neutral point and earth to access an inductor coil, single phase ground fault, the use of consumer Coil inductor current to compensate for the capacitance to ground current, the current flow through the ground point is reduced to self-extinction range, which features a line of single phase, g

您可能关注的文档

文档评论(0)

jiupshaieuk12 + 关注
实名认证
内容提供者

该用户很懒,什么也没介绍

版权声明书
用户编号:6212135231000003

1亿VIP精品文档

相关文档