一级建筑师考试资料暖(First class architect examination material is warm).docVIP

一级建筑师考试资料暖(First class architect examination material is warm).doc

  1. 1、本文档共19页,可阅读全部内容。
  2. 2、原创力文档(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。
  3. 3、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载
  4. 4、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
  5. 5、该文档为VIP文档,如果想要下载,成为VIP会员后,下载免费。
  6. 6、成为VIP后,下载本文档将扣除1次下载权益。下载后,不支持退款、换文档。如有疑问请联系我们
  7. 7、成为VIP后,您将拥有八大权益,权益包括:VIP文档下载权益、阅读免打扰、文档格式转换、高级专利检索、专属身份标志、高级客服、多端互通、版权登记。
  8. 8、VIP文档为合作方或网友上传,每下载1次, 网站将根据用户上传文档的质量评分、类型等,对文档贡献者给予高额补贴、流量扶持。如果你也想贡献VIP文档。上传文档
查看更多
一级建筑师考试资料暖(First class architect examination material is warm)

一级建筑师考试资料暖(First class architect examination material is warm) 4.5 warm (20) 1. heating temperature lower than 100 DEG C, gasification and the possibility of small, the normal operation of the system with high reliability In the premise of lower than 100 DEG C, the temperature as high as possible, to reduce the heat dissipation area 2. high-rise building heating system, building height of more than 50M should be separated from the vertical More than 50 meters high pressure system selection of radiator is not easy 3. calculation of heating load, additional heat loss of enclosure structure should be determined according to the percentage of the basic consumption, the orientation correction factor The north, northeast, East and west northwest of 0 ~ 10% -5% in Southeast and southwest South -15 ~ -30% ~ -15% -10 When the winter sunshine rate is less than 35% Fixed rate of southeast, southwest and south of the building envelope is -10 ~ 0% The East and west to the building envelope is not correct 4. by building doors and window heat loss accounted for the total energy consumption of buildings 2/3 5. heating medium for steam, should not be used when using iron steel radiator, radiator, and the radiator should withstand the pressure to adapt to; Steam heating system working pressure should not exceed 0.2MPa 6. when the room height is 6 meters, the height of the retaining structure of additional heat loss is 4% When the building outside the window and wall ratio is greater than 50%, 10% additional heat loss of enclosure structure Comparison of 7. hot water heating and steam heating, room temperature fluctuation has obvious advantages of small The characteristics of 8. gravity circulation hot water heating system does not need the power, energy saving, but the pressure is small, only suitable for the effective radius of not more than 50 meters, three storey small building 9. Malostranska Residence should be for the next time the mechanical circulation heating system with dua

文档评论(0)

jgx3536 + 关注
实名认证
文档贡献者

该用户很懒,什么也没介绍

版权声明书
用户编号:6111134150000003

1亿VIP精品文档

相关文档