空压机故障排除(Troubleshooting of air compressor).doc

空压机故障排除(Troubleshooting of air compressor).doc

  1. 1、本文档共19页,可阅读全部内容。
  2. 2、原创力文档(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。
  3. 3、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载
  4. 4、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
查看更多
空压机故障排除(Troubleshooting of air compressor)

空压机故障排除(Troubleshooting of air compressor) Cannot start 1. failure phenomena and possible causes Troubleshooting method The power is not connected; Close the power switch to turn on the power. Control circuit fuse fuse; Replace the fuse, find out the cause and solve it. Exhaust temperature is too high to cause high temperature shutdown According to the exhaust temperature is too high or oil temperature is too high section to solve, and then restart the compressor. Thermal overload relay is disconnected; Correct the overload reason and reset the thermal overload device. Voltage is too low; Please check the input voltage with the power department and compare with the motor terminal voltage. To check the cause of the voltage is too low. Power failure; Check the power supply section. Loose wiring; Check all wiring endpoints and fasten them. Temperature sensor fault; Check sensors and contact maintenance with professionals. Transformer fault; Check secondary voltage of transformer. Unexpected stop Failure phenomena and possible causes Troubleshooting method Exhaust temperature is too high; According to the exhaust temperature or oil injection temperature is too high part of the content processing. Then restart the machine. Power failure; Check the power supply section. High temperature switch fault; Contact the operation and maintenance personnel. Loose wiring; Check all wiring endpoints and fasten them. Thermal overload relay is disconnected Failure phenomena and possible causes Troubleshooting method Exhaust pressure is too high; Lower the unloading pressure a little. Voltage is too low; Check the input voltage and current at full load. The thermal overload relay is loose; Tighten connection screw for thermal overload relay. The thermal overload relay is not set properly; Check motor nameplate and compare with overload relay setting. Motor or starter wiring is loose; Check all connections for tightening. Motor fault; The motor and starter wiring shall be checked before

您可能关注的文档

文档评论(0)

f8r9t5c + 关注
实名认证
内容提供者

该用户很懒,什么也没介绍

版权声明书
用户编号:8000054077000003

1亿VIP精品文档

相关文档