通力3000故障代码(Kone 3000 fault code)
通力3000故障代码(Kone 3000 fault code)
Kone 3000 fault code
Code
Fault name
Reason
Operate
Recover
Test
0001
Long drive time
The position signal 30/B30 does not change after a period of running time.
Immediate stop
Turn off the electricity
Slow the elevator stopped under 77:U, unplug the 0.61:U/N, to express
0004
Three consecutive simultaneous failures
3 consecutive simultaneous operation, can not receive the correct 77:U/N, 61U/N, 30 signals
After 3 failures, stop at the terminal
Turn off the electricity
-
0007
The gate signal 30/B30 is jammed
After starting a period of time, the falling edge of the 30/B30 signal is not detected, and the gate signal 30/B30 is always valid
Run to the goal floor and open the door
Power off or repair
The 30 (B30) signal on the shorted LCECCB (XB24), the lowest pin of the -XB21
0008
NVRAM damage or capacity is not enough
When power is transmitted, the capacity of NVRAM is not enough
- change the NVRAM
-
0014
The gate area monitoring circuit is not released
Any one of the 486443:1443:2 has no pull in 2 consecutive runs
Run to destination layer out of service
Turn off the electricity
Runtime makes 443:2 (LCEADO) not pull in
0015
The gate monitoring circuit is not attracted
Any one of the 486443:1443:2 is not released in 2 consecutive runs
The runtime keeps 443:2 (LCEADO) in hold
0021
The safety loop is blocked
Safety loop input 1 no voltage
Immediate stop
Safety loop connection
Disconnect the safety circuit
0022
The running well lock is disconnected
Safety loop input 3 no voltage
Immediate stop
Lock on hoistway door
Use the key to open the hall door or unplug the LCE230 XH2
0023
The door lock is broken at the time of operation
Safety loop input 2 no voltage
Immediate stop
Car door lock
-
0025
Boot enable fault
When the elevator stops, the main contactor is not released
Not started
Main contactor release
Keep 201:1 or 201:2 or 204 all the time
0026
The drive system is out of order
The drive system detected a fault (V3F, OK, lights are not lit)
您可能关注的文档
- 近代史单选(Modern history radio).doc
- 运用冯天有手法治疗颈椎病138例.doc
- 近代史纲要(多选)(Outline of modern history (s)).doc
- 近代史试题(Modern history examination questions).doc
- 近代改良主义思想家薛福成简介(A brief introduction to Xue Fucheng, a modern reformist thinker).doc
- 近代史纲要模拟题(Modern history outline).doc
- 近八成职业病是尘肺病(Nearly 80% occupational diseases are pneumoconiosis).doc
- 近反义词成语(Near antonyms).doc
- 近代数学家华蘅芳与中国第一台蒸汽机(Modern mathematician Hua Hengfang and China's first steam engine).doc
- 近期塑料期货分析(Recent plastics futures analysis).doc
文档评论(0)