2号发电机由热备用转检修(No. 2 generator is switched from hot standby to overhaul)

2号发电机由热备用转检修(No. 2 generator is switched from hot standby to overhaul) Operator orders, start operation The operation value is long and the operation is started Check generator No. 2 in stop mode Check the No. 2 excitation system, the excitation switch, the rotor, one point grounding protection plate, 1LP, the correct name Withdraw from No. 2 excitation system, excitation switch, rotor, one point grounding protection plate 1LP Check the No. 2 excitation system, the excitation switch, the rotor of the switchboard, one point grounding protection plate, and the 1LP have been withdrawn Check the No. 2 excitation system, excitation switch cabinet Rotor Overvoltage protection pressure plate 2LP, the name is correct Switch out the overvoltage protection plate of the rotor of the excitation switch box of No. 2 excitation system 2LP Check No. 2 excitation system, excitation switch, rotor, overvoltage protection plate, 2LP have exited Check the DC section I bus feeder on the machine No. 2 excitation power switch double double correct Switch off No. 2 exciter power switch on the DC section I bus feeder cabinet Check the DC section bus feeder cabinet, No. 2 excitation power switch has been disconnected Check 10KV 2 generator outlet 021 circuit breaker double number correctly Check 10KV No. 2 generator outlet 021 circuit breaker. The mechanical position is indicated in O position Check 10KV 2 generator outlet 021 breaker cabinet remote / local control handle name is correct Cut 10KV No. 2 generator outlet, 021 breaker cabinet remote / local control handle to on the spot position Check 10KV No. 2 generator outlet, 021 circuit breaker cabinet, remote / local control handle in on the spot position If 10KV 2 generator 021 circuit breaker to test Check 10KV No. 2 generator exit, 021 circuit breaker, hand truck in test position Check 10KV 2 generator outlet 021 circuit breaker control power switch MCB1 double correct Disconnect 10KV 2 generator outlet 021 circuit breaker control power

您可能关注的文档

文档评论(0)

f8r9t5c + 关注
实名认证
文档贡献者

该用户很懒,什么也没介绍

版权声明书
用户编号:8000054077000003

1亿VIP精品文档

相关文档