某卷烟厂空调风系统能耗测试与分析
第28 卷第3 期 建筑 热 能通 风 空 调 Vol.28 No.3
2009 年6 月 Building Energy Environment Jun. 2009.76~79
文章编号:1003-0344(2009)03-076-4
某卷烟厂空调风系统能耗测试与分析
1 2
巩超 熊周喻
1 山东中烟工业公司济南卷烟厂
2 北京康孚环境控制有限公司
摘 要:卷烟厂中央空调系统具有风量大、能耗高、制冷机组全年运行周期长的特点。本文对某卷烟厂联合工房空
调风系统的能耗状况进行了现场测试,以此为基础分析了该空调风系统存在的问题,最后根据分析结果提出了适
当的改进措施。
关键词:卷烟厂中央空调能耗测试
Measurement and Analysis of Central Air-conditioning Energy Consumption in a
Tobacco Factory
1 2
GONG Chao , XIONG Zhou-yu
1 Jinan Cigarette Factory, China Tobacco Shandong Industrial Corporation
2 Beijing Comfort Environmental Controls Ltd.
Abstract: With a huge supply air and long running time, the energy consumption of central air-conditioning system of
tobacco factory is much more than other central air-conditioning system. Based on the measurement of a central
air-conditioning in a tobacco factory, some existing disadvantages of this system were point out. Finally, a series
improvement was brought forward to cut down the energy consumption availably.
Keywords: tobacco factory, central air conditioning, energy consumption, measurement
0 引言 间、装箱区及高架库等组成。本文介绍了对该联合工
房空调风系统的能耗检测过程及结果分析,并根据分
卷烟在生产制造过程中,需要维持一个恒温恒湿 析结果提出了系列的改进措施。
的生产环境。卷烟厂的中央空调系统具有空调面积
大、全年保持恒温恒湿、车间内工艺设备发热量多、变 1 空调风系统基本信息
化快等特点,因此空调系统风量大、能耗高、制冷机组
全年运行周期长[1]。据不完全统计,空调制冷能耗约占 该联合工房空调风系统由27 台空调箱组成,分别
烟草生产总能耗的1/3 左右[2] ,故对空调系统进行有