- 1、本文档共7页,可阅读全部内容。
- 2、原创力文档(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。
- 3、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载。
- 4、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
查看更多
单能量对双源双能量CT心肌灌注成像中线束硬化
DOI:10.16016/j.1000-5404.201411236
双源双能量CT心肌灌注扫描的单能量成像对线束硬化伪影的校正研究
魏 淼,王思杭,温家华,刘 洋,吕发金 (400016重庆,重庆医科大学附属第一医院放射科)
【摘要】目的 观察双能量CT心肌灌注成像中线束硬化伪影(beam-hardening,BH)的好发部位,比较不同单能量成像对线束硬化伪影的校正效果和图像质量。方法 对84例需行心脏CT增强检查的拟诊或确诊冠心病患者进行双源双能量CT(100/Sn140kVp)P0.05);左心室的基底段伪影最明显(36.5%,100/274),其次为间隔壁(25.91%)、上腔静脉旁段(24.82%)、后壁(12.77%)(P0.05);心肌伪影区碘含量(-2.37±0.84)mgI/g低于非伪影区碘含量(3.5±0.92)mgI/g(t=-19.36,P0.001);85keV的非伪影心肌CT值(93.52±18.52)HU与120kV(96.06±16.32)HU最接近,CT值的组间差异有统计学意义(P0.01);85keV的SD最小[(12.98±3.16),P0.01],非伪影心肌的SNR: 75keV(6.89±1.79)与85keV(6.5±1.7)较高,二者无明显差别(t=1.5,P=0.14),CNR: 75keV最高[(18.79±6.76),P0.001],85keV(15.4±5.67)与65keV(15.53±4.56)之间无明显差别(t=-0.27, P =0.79);图像质量评分:85keV最高,两名诊断医生对六组图像进行评分一致性高度一致(Kappa=0.79,P0.001)。结论:左心室的基底段、间隔壁和上腔静脉旁易出现线束硬化伪影;正常心肌密度在85keV与混合能量120kV最接近,85keV能在最有效纠正线束硬化伪影的同时保证较好的图像质量。
【关键词】双源双能量CT心肌灌注扫描;单能量成像;线束硬化伪影;图像质量
【中图分类号】R814.42 【文献标志码】The study of Beam-hardening correction for monochromatic imaging via dual-energy myocardial perfusing imaging with dual-source CT
Wei Miao Wang Sihang Wen Jiahua Liu Yang LV Fajin(Department of Radiology the First Affiliated Hospital of Chongqing Medical University,Chongqing China,400016)
【Abstract】Objective:To observe the high incidence site of beam-hardening artifacts in dual-energy CT myocardial perfusing imaging,and compare the image quality and effcet for beam-hardening correcting of different monochromatic energe images via dual-energy myocardial perfusing imaging with dual-source CT.Methods: 84 patients requiring cardiac enhancement-CT examination were underwent dual-energy (100/Sn140kVp)myocardial perfusing imaging with dual-source CT ,who were suspected or definited coronary artery disease enrolled.Apllicating specialized post-processing software with results of iodine maps and.monoenergetic images under 65keV,75keV,85keV,95keV,105keV.To count the number of beam-hardening artifacts with control of M image(weighted Polychromatic 120kV)which is automated system generation. Comprehensive
您可能关注的文档
最近下载
- 大学美育 课件 第8章 中国艺术美 第一节 书法美.pptx
- 9型人格108道测试题.doc
- 《新能源变换技术》课件——3.2.单相桥式全控整流电路结构及电阻性负载工作原理.pptx VIP
- 绿色贸易壁垒影响下浙江省农产品出口问题研究分析 国际贸易专业.doc
- 《新能源变换技术》课件——3.1.2 单相半波可控整流电路结构及电感性负载工作原理(二).pptx VIP
- 呼吸系统疾病的预防与保健PPT.pptx VIP
- 小学信息技术冀教版四年级下册 我们生活在信息时代 课件.pptx
- 幼儿园中班散文欣赏《芽儿》教学课件.ppt
- 2024年江苏护理职业学院单招职业技能测试题库及答案(易错题).docx VIP
- 老年人心理健康量表(维度划分+评分方式).docx
文档评论(0)