屏蔽泵 轴位移 使用说明书
Model DCH-106 Axial Displacement
Monitor
USER’S MANUAL
Dalian Hermetic Pump Co., Ltd.
I. Introduction
As the awareness of environment protection in all walks of life is being built up,
non-leakage pumps such as canned motor pumps and magnetic pumps are being
used widely in many industries. One of the key technologies for canned motor
pumps is the balance of axial force on the rotating part. In case such a balance of
axial force is broken in operation, the canned motor pump will be damaged rapidly
affecting the normal production process. Model DCH-106 axial displacement
monitor is designed to monitor any axial displacement of the rotating part in the
canned motor pump. It can detect any change in the axial balance caused by
abnormality and give alarm signals.
II. Work principle
Working with the principle of current vortex, this monitor is comprised of two parts,
the measure meter and the magnetic sensor. The measure meter is installed on
the rear bearing block made of nonmagnetic materials, while the magnetic sensor
is installed on the screw at the shaft end and moves with the rotating part. Any
change in the gap between the two parts corresponds to the change in the
magnetic field strength detected by the measure meter. Therefore, the measure
meter can detect any axial displacement of the rotating part through any change
in the magnetic field strength.
This monitor shows the detected displacement on the LED digital display at the
field. It gives LED indications with the normal operation zone (the green LED
lights up), the alarm zone (#1 red LED lights up), or the interlocking shutdown
zone (#2 red LED lights up), and can output the switching value and the 4-20 mA
remote signal.
III. Specification
1. Working temperature:
≤ 100°C for Model DCH-1