R290安全性评估报告-EN

REPORT 30/01/2009 DRA-09-96666-01473A Safety study relating to compressors for a refrigerating unit running on propane, for their certification in compliance with the directive ATEX 94/9/CE Safety study relating to compressors for a refrigerating unit running on propane, for their certification in compliance with the directive ATEX 94/9/CE TREVOUX Site (01) Customer: DANFOSS COMMERCIAL COMPRESSORS Company People having taken part in the study: J. CHAINEAUX, S. LEMAIRE Ref : DRA-09-96666-01473A Page 1 of 17 FOREWORD This report was established on the basis of the information provided to INERIS, the data (scientific or technical) available and objective and regulation applicable. The responsibility for the INERIS could not be committed if information which was communicated is incomplete or erroneous. The opinions, recommendations, or equivalent which would be carried by INERIS within the framework of the services which are entrusted to it, can contribute to the decision-making. Being given the mission which falls on INERIS from its decree of creation, INERIS does not intervene in the decision-making itself. The responsibility for INERIS cannot thus replace that of the decision maker. The recipient will completely use the results included in this report or if not in an objective way. Its use in the form of extracts or of notes of synthesis will be made under only and whole responsibility for the recipient. It is the same for any modification which would be made there. INERIS releases any responsibility for each use of the report apart from the destination of the service. Redaction