二氧化氯发生装置控制系统的研究-机械电子工程专业论文

沈阳理工大学硕士学位论文 Abstract A kind of Chlorine Dioxide Generator Control System used in the field of water purification is designed based on the AT89C52 single chip microcontroller.The reaction of hydrochloric acid and sodium chlorite to generate Chlorine Dioxide is used to the device.The control system has two parts of scene controller and long-distance controller. The stroke frequency which is sent to the metering pump by the way of pulse can be got by scene controller according to the real-time value of the water flow and the concentration of the Chlorine Dioxide detected by long-distance controller,the pump’s stroke frequency is controlled and the concentration of the Chlorine Dioxide in the water can be controlled precisely.The system is a closed-loop controler and is used to disinfect water.The long-distance controller can monitor the status of the scene and display the current concentration.The pump will be stopped when the system has some fault information such as water shortage,solution shortage,pipeline issues and so on.At the same time,the light will be on and the buzzer will be rung.The scene controller and the long-distance controller use RS-485 communication. The process of the Chlorine Dioxide Generator Control System is analysed particularly in the text,In this foundation,the overall design is done;It also describes the hardware and software which constitute the scene controller and the long-distance controller,such as the LCD module,the key module,the fault information module,the watchdog,the pump control,the sensor,the data acquisition and processing module and the RS-485 communication.At present,the prototype has been successfully debugged,it is evinced that all the function designed can be carried out. Key words:water purification;Chlorine Dioxide;single chip microcontroller;metering pump;RS-485 communication 沈阳理工大学 硕士学位论文原创性声明 本人郑重声明:本论文的所有工作,是在导师的指导下,由作者本 人独立完成的。有关观点、方法、数据和文献的引用已在文中指出, 并与参考文献相对应。除文中已注明引用的内容外,本论文不包含任 何其他个人或集体已经公开发表

您可能关注的文档

文档评论(0)

peili2018 + 关注
实名认证
内容提供者

该用户很懒,什么也没介绍

1亿VIP精品文档

相关文档