ICS 27.100 F 24 备案号:40029-2013 中华人民共和国电力行业标准 DL/T 1203—2013 火力发电厂水汽中氯离子含量测定方法 硫氰酸汞分光光度法 Analyticalmethodsforchlorideinsteamandwaterinfossilfuelpowerplants Spectrophotometricmethodusingmercurysulfocyanide 2013-03-07发布 2013-08-01实施 国家能源局 发 布 DL/T 1203 — 2013 目 次 前言 ··········································Ⅱ 1 范围·········································1 2 规范性引用文件 ····································1 3 方法提要 ·······································1 4 试剂 ·········································1 5 仪器 ·········································1 6 分析步骤 ·······································1 7 结果的表述······································2 8 精密度 ········································2 9 分析报告 ·······································2 I DL/T 1203 — 2013 前 言 本标准由中国电力企业联合会提出。 本标准由电力行业电厂化学标准化技术委员会归口。 本标准起草单位:西安热工研究院有限公司、山东电力研究院、湖北电力试验研究院。 本标准主要起草人:田利、王广珠、周少玲、刘绍银、沈肖湘、史庆琳。 本标准在执行过程中的意见或建议反馈至中国电力企业联合会标准化管理中心(北京市白广路二 条一号,100761)。 II DL/T 1203 — 2013 火力发电厂水汽中氯离子含量测定方法 硫氰酸汞分光光度法 1 范围 本标准规定了火力发电厂水汽中氯离子的硫氰酸汞分光光度测定方法。 本标准适用于水汽中氯离子含量在25μg/L~1000μg/L 时的测定。 2 规范性引用文件 下列文件对于本文件的应用是必不可少的。凡是注日期的引用文件,仅注日期的版本适用于本文 件。凡是不注日期的引用文件,其最新版本(包括所有的修改单)适用于本文件。 GB/T6903 锅炉用水和冷却水分析方法 通则 DL/T502.2 火力发电厂水汽分析方法 第2部分:水汽样品的采集 3 方法提要 在硝酸介质中,氯离子与硫氰酸汞发生反应,形成氯化汞并释放出硫氰酸根,此时在溶液中加入 三价铁,三价铁与硫氰酸根形成橘红色络合物,其显色强度与氯离子含量有关,浓度与吸光度呈线性 关系。 4 试剂 4.1 试剂水:应符合GB/T6903规定的Ⅰ级试剂水的要求。 4.2 试剂纯度:试剂纯度应符合GB/T6903的要求。 4.3 硝酸(5mol/L):移取380mL浓硝酸,加入600mL试剂水,冷却至室

文档评论(0)

ormition + 关注
实名认证
文档贡献者

该用户很懒,什么也没介绍

1亿VIP精品文档

相关文档