Hybrid Reflective-crack Relief System At Greater Peoria :混型反射裂缝的救济制度在大皮奥里亚.pptVIP

Hybrid Reflective-crack Relief System At Greater Peoria :混型反射裂缝的救济制度在大皮奥里亚.ppt

  1. 1、原创力文档(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。。
  2. 2、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载
  3. 3、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
  4. 4、该文档为VIP文档,如果想要下载,成为VIP会员后,下载免费。
  5. 5、成为VIP后,下载本文档将扣除1次下载权益。下载后,不支持退款、换文档。如有疑问请联系我们
  6. 6、成为VIP后,您将拥有八大权益,权益包括:VIP文档下载权益、阅读免打扰、文档格式转换、高级专利检索、专属身份标志、高级客服、多端互通、版权登记。
  7. 7、VIP文档为合作方或网友上传,每下载1次, 网站将根据用户上传文档的质量评分、类型等,对文档贡献者给予高额补贴、流量扶持。如果你也想贡献VIP文档。上传文档
查看更多
Hybrid Reflective-crack Relief System At Greater Peoria :混型反射裂缝的救济制度在大皮奥里亚

Extent of Project Taxiway-E: Main taxiway parallel to Rwy 13-31 Approximately 1780 m C/L length (5800 ft) Project involved resurfacing and widening in some areas * Rehabilitation Strategy Existing conditions were very severe: Reflective, block, and longitudinal (cold joint) cracks Reflective cracks were very wide and cupped Reflective cracks were widely spaced (avg = 100’) Cold winters, freeze-thaw, heavy aircraft (727, DC-8, C-130 [Air National Guard], Antonov [Caterpillar HQ]) Initially, the ISAC (Interlayer Stress Absorbing Composite) was proposed. However, due to the very wide crack spacing, predicted horizontal joint movements were predicted to be too severe for the standard ISAC strip treatment. The U of I research team was tasked with developing a variant on the ISAC system. FEA showed that a thicker stress absorbing layer was needed. * Kim, J., and W. G. Buttlar, Analysis of Reflective Crack Control System Involving Reinforcing Grid over Base-Isolating Interlayer Mixture, ASCE Journal of Transportation Engineering, Vol. 128, No. 4, pp. 375-384, 2002. Rehabilitation Strategy * A hybrid reflective crack relief system (RCRS) was developed using 3D FEA, that combines: Reinforcement grid (restrict movement, reinforce HMA) Thick (50 mm) stress absorbing membrane interlayer (base isolation, protect/isolate grid)…field produced (too thick for pre-fab) Schematic of Hybrid RCRS Base isolation layer was designed as strip-type inlay (50 mm thick), or ‘partial-depth’ patch * Subgrade Aggregate Base (P154) Existing AC Pavement (P201) Interlayer AC Mix (50 mm) Fiberglass Grid AC Overlay 115 mm 510 mm 190 mm Temperature Sensors 1200 mm 1500 mm RCRS Material Details Strain Tolerant Mixture 4.75 mm top aggregate size sand mixture 8% asphalt content and 3.5% air voids at 50 gyrations PG 76-31 Binder Grid System: GlasGrid? 8502 Fabric 12.5 mm x 12.5 mm (0.5 x 0.5 inch) opening 1.5 m wide strip application over base isolation interlayer Pressure-activated coating * RC

文档评论(0)

181****7127 + 关注
实名认证
文档贡献者

该用户很懒,什么也没介绍

1亿VIP精品文档

相关文档