惰气系统操作规程
I.G.S.OPERATION GUIDE
一、启动程序START UP PROCEDURES
确认锅炉提供的烟气含氧量达到或低于5%。
Ensure boiler is producing flue gas with an oxygen content of 5% by volume or less.
确认所有的控制电源,警报及自动关闭操作正常。
Ensure that power is available for all control, alarm and automatic shutdown operations.
确认所选的洗涤塔和甲板水封泵是对其正常供水且水位正常。
Ensure that the quantity of water required by the scrubber and deck water seal is being maintained satisfactorily by the pumps selected for this duty.
试验洗涤塔和甲板水封的警报。
Test operation of the alarm and shutdown featured of the system dependent upon the throughput of water in the scrubber and deck seal.
确认除气所用的空气进口阀关闭且用盲板盲死。
Check that the gas freeing fresh air inlet valves ,where fitted, are shut and the blanks in position are secure.
关闭空气密封系统。
Shut off the air to any air sealing arrangements for the boiler uptake valve.
打开烟气隔离阀。
Open the flue gas-isolating valve.
打开所选风机的进口阀,如使用一台风机,确认另一台的进出口阀关闭。
Open the selected fan suction valve. Ensure that the other fan suction and discharge valves are shut unless it is intended to use both fans simultaneously.
启动风机。
Start the fan.
试验风机的“故障”警报。
Test fan“FAILURE”alarm.
打开风机的出口阀。
Open the fan outlet valve.
打开主控阀。
Open the main control valve.
确认氧气含量达5%或低于5%,然后关闭主控阀与甲板水封之间的透气阀。
Check that oxygen content is 5% by volume or less, and then close the vent to atmosphere between the main control and the deck seal unit.
氧气分析仪至少提前30分钟启动
Note: Oxygen analyzer require as much as 30 minutes before accurate reading can be obtained.
此时惰气系统已经准备好给货舱充惰。
The inert gas system is now ready to deliver gas to the cargo tanks.
二、关闭程序SHUTDOWN PROCEDURES
当所有货舱的含氧量低于8%且舱压符合要求时,关闭甲板隔离/止回阀。
When all tank atmospheres have been checked for an oxygen level of not more than 8% and the required pressure in the tank has been obtained, shut the deck isolating/non-return valve.
打开主控阀与甲板水封之间的透气阀。
Open vent to atmospheres between the main control valve and deck water seal.
关闭主控阀。
Shut the main control valve.
关闭惰气风机。
Shut down the inert gas fan.
关闭风机进口与出口筏。当风机的驱动