迅达电梯3300外呼板设定.pdfVIP

  • 367
  • 0
  • 约7.11千字
  • 约 4页
  • 2019-08-05 发布于山东
  • 举报
Checklist LOP5 Help us to improve the quality of our products and processes! In case one of the products listed in the next section has to be replaced due to functional problems, proceed as follows: 1. Fill-in all the fields of the checklist 2. Scan and attach the checklist in PDF format to section 11 of the GCM claim or Fax the checklist with the GCM claim id. Reference to +0512 IMPORTANT: if the checklist is not completely filled-in and communicated, the GCM claim class will be changed. Applicable product ID No. With display: LOP5D;LOP5U;LOP52 LOPM5BD;LOPM5BU;LOPM5B2 LOPM5BDD;LOPM5B2DU;LOPM5B2D LOPM5DD;LOPM5UD;LOPM52D W/O display: LOPM5D;LOPM5U;LOPM52 LOP5BD;LOP5BU;LOP5B2 ID: -26C 55503735 55503738 Preliminary Checks Action in case not OK Done For sensitive LOP ’s: if no operation or sensitivity CF7,PA2,Value: 1: high 7: low not OK: modify the LOP sensitivity In case the LOP cannot be configured or the Make an BioBus device address cleaning configuration was lost, perform the action on the Controller SW ≤9.2X: CF94, PA 0, Value 1 right and then configure every LOP according Controller SW ≥9.3X: CF40, Level 0, PA 99, Value 1 to the instruction on next page IMPORTANT: after this operation, every LOP and other (Only Simplex: Duplex see section on K608208) devices on the BioBus has to be reconfigured. Questions