厦门±320kV柔性直流电缆工程技术研究.doc

  1. 1、原创力文档(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。。
  2. 2、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载
  3. 3、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
查看更多
PAGE PAGE 1 论文15-08《厦门±320 kV柔性直流电缆工程电缆选型和敷设》 Research on Cable Section and Laying of Xiamen ±320 kV Flexible HVDC Cable Engineering 严有祥1,方晓临3,张伟刚1,赵健康2,陈铮铮2,陈朝晖1 (1.国网厦门供电公司,厦门 361006;2.中国电力科学研究院,武汉 430074; 3.国网莆田供电公司,莆田 351100由于第二作者单位变动,因此改动) 由于第二作者单位变动,因此改动 YAN Youxiang1, FANG Xiaolin3, ZHANG Weigang1,ZHAO Jiankang2, CHEN Zhengzheng2,CHEN Chaohui1 (1.State Grid Xiamen Electric Power Supply Company, Xiamen 361006,China; 2.China Electric Power Research Institute, Wuhan 430074,China; 3. School of Electrical Engineering and Automation, Xiamen University of Technology, Xiamen 361024,China 摘 要:厦门±320kV柔性直流输电工程是目前世界上电压等级最高的柔性直流输电工程,该工程面临诸多问题。为此,探讨了该工程交联电缆及附件的选型原则、电缆运行温度、单段电缆长度、载流量截面、电缆敷设方式及交直流电缆共沟敷设等参数,为该工程构建中的技术难点提供了合理的解决方案。结果表明:当该工程中直流电缆的长期运行温度取70℃时,电缆具有较好的绝缘性能;当电缆导体的截面积应选择取1800mm2时,载流量为1617A,满足工程要求;当单段电缆长度取962m时,可减少电缆接头、降低工程造价;电缆附件应选择现场注塑式;暂态和稳态情况下,采用交直流电缆共沟敷设可以满足安全稳定要求。什么要求?请用修订模式查看中文摘要这么修改是否合适? 什么要求? 请用修订模式查看中文摘要这么修改是否合适? 关键词:柔性直流;直流电缆;电缆敷设;电缆选型;工作温度关键词6~9个,请添加。已添加;电缆长度;电缆接头 关键词6~9个,请添加。 已添加 Abstract: Xiamen ±320kV flexible HVDC engineering is the highest voltage grade flexible HVDC engineering in the world. The engineering faces a lot of problems. Therefore, it is discussed that selection principle of flexible HVDC cable and cable accessories, cable running temperature, single segment cable length, cable section selection and current carrying capacity, AC and DC power cables common cable tunnel laying , these parameters are analysed in this paper to supply reasonable solutions for engineering difficulties. The result shows that as flexible HVDC cable running temperature is 70℃ ,it can have a good insulation performance, and as cable conductor section is 1800mm2 and current carrying capacity is 1617A, it satisfies engineering requirement. as the single segment cable length is 962m, the number of joints and cost can be decreased. Cable accessories should choose injection in-site type. It meets the security and stability requirement by AC and DC power cables commo

文档评论(0)

136****3783 + 关注
实名认证
内容提供者

该用户很懒,什么也没介绍

1亿VIP精品文档

相关文档