* This cooling system (HV water pump with motor) always activates when the power mode is selected to READY-ON state. Radiator for inverter is located above A/C condenser 当处于READY-ON模式时,冷却系统(HV水泵)总处于激活状态。 变频器散热器位于A/C压缩机上面。 * * Measure the volume of the drained coolant, and replace it with a volume that is greater than the drained coolant (as a guide for bleeding air). 测量排放的冷却液量,用多于排放量的冷却液加注() * Active Test: Powertrain “Hybrid Control “Active Test “Active the Water Pump“ Point: Air bleeding is completed if the operating sound of the water pump decreases and the flow of the coolant in the res