液化石油气站气电联动紧急切断控制系统改造工程概述.pdf

液化石油气站气电联动紧急切断控制系统改造工程概述.pdf

企业之窗 第 32 卷 第 4 期 液化石油气站气电联动紧急切断 控制系统改造工程概述 杨剑 1 汤吉光 2 (1. 珠海市安粤科技有限公司 珠海 519002) (2. 珠海新海燃气工程有限公司 珠海 519002) 摘 要:针对传统的、老旧的液化石油气站,设计了一套气电联动紧急切断控制系统,并用于气站改造。 控制系统分为电、气两条线路,并从材料设备选择、改造原理及方法、改造优势三个方面进行阐述,对液化 石油气站的紧急切断系统改造具有一定的参考价值。 关键词:液化石油气站 气电联动 紧急切断系统 Summarize of Reconstruction Project for Pneumatic Linkage Urgent Shut Control System of LPG Station Yang Jianyun1 Tang Jiguang2 (1. Zhuhai City of Guangdong Science and Technology Co. Ltd Zhuhai 519002) (2. Zhuhai newocean of gas engineering Co. Ltd Zhuhai 519002) Abstract This paper introduced the design of a pneumatic linkage urgent shut control system for traditional and old LPG station, which was used in reconstruction. The control system was divided into electricity lines and gas lines explained from three aspects on materials and equipment selection, principle and method of reconstruction, the advantage of reconstruction, which had a certain reference value for urgent shut control system of LPG station. Keywords LPG station Pneumatic linkage Urgent shut control system 中图分类号: X924.2 文献标识码:B 文章编号:1673-257X(2016)04-0087-04 DOI: 10.3969/j.issn.1673-257X.2016.04.017 1 引言 爆炸极限低,与空气混合会形成爆炸混合物[1] ,在生产、 贮运和使用过程中易引起爆炸火灾事故,尤其在液化 液化石油气 (LPG) 是在开采和炼制石油的过程 石油气站的贮罐区,贮罐集中且贮量大,一旦发生泄 中,以副产品的形式获得的一部分碳氢化合物,作为 漏引起爆炸火灾事故,后果不堪设想 [2]。 清洁能源,其运输和使用的便捷性,使其广泛应用于 传统的、老旧的液化石油气站为应对紧急情况的 目前的工业生产和日常生活中。但同时,因其闪点、 产生,一般采用的是液动紧急切断阀来切断气、液相 来源。液动紧急切断阀是与远距离手摇油泵配套使用,

文档评论(0)

1亿VIP精品文档

相关文档