- 1
- 0
- 约2.02万字
- 约 17页
- 2020-08-28 发布于浙江
- 举报
Noise Vibration and Harshness (NVH)
5) Diagnosis
- Change the torque converter bolting position
There are 4 variations of mounting position between a torque converter and a drive plate.
Power-train vibration can be possibly coming from the weight unbalance between a torque
converter and a crankshaft.
Fix the torque converter on the best position among 1-1, 1-2, 1-3, 1-4.
- Dynamic balance of Crankshaft
▶ Specification : 10~15g / 320~380rpm
41
Noise Vibration and Harshness (NVH)
- Dynamic balance of Torque Converter
▶ Specification : 20g ↓ / 550~650rpm
- HB Measurement of the defected torque converter
42
Noise Vibration and Harshness (NVH)
* Measurement of HB (at single point)
Measuring Specification Measurement
Judgement
item (mm) (mm)
HB 108.28 Max. 107.963 OK
* Measurement of HB (Min/Max)
Specification Measurement Declination
Measuring item Judgement
(mm) (mm) (mm)
Defected Part 108.28 Max. 108.13 Max. 106.42 Min. 1.71 NG
HB
New 108.28 Max. 106.65 Max. 106.45 Min. 0.2 OK
6) Cause
: Unbalance of torque converter
[Defected Torque Converter - poor assembly (welding) between Impeller
shell and pump drive hub]