Pr?sentationstitel | Stand April 2016 |;Agenda; Function ; A function is a parameterizable module without memory, i.e. it always delivers the same results from the same input parameters A function delivers the results back to the accumulator This means, that a function can only deliver a data element as a result ; A function block is a module that delivers one or more values, when executed There are IEC FBs, Manufacturer FBs, and User FBs A function block can buffer values ;A program delivers one or more variables, when executed Programs are globally known in the entire project A program can buffer values Additional functions can start from the PLC_PRG main program ;Exercise 1;;; Write a program in FBD or CFC ; Write a program in LD ; Add an ON delay for output K2 with a 4.75 s delay time to the Program from Exercise 4 ; With the aid of two “TP” function blocks, program a flashing light that flashes at a clock rate of 100 ms ;4 - 14 WAGO Kontakttechnik GmbH Co. KG; Generate a PLC_VISU with the elements depicted. The system is switched using S1 to “RUN” and using S2 to “STOP”. Using S3 simulates the “light sensor” that is used for counting the parts. The “engine” runs as long as the counter has not reached the value 5 and the system is set to “RUN”. The counter could be reseted by using S4 (container changed). ;Realize a boiler control by means of which a water boiler can be filled and heated. The system should be started/ stopped using a start/ stop button. At a filling level of 4000 liters, the valve should be closed. The fill level is determined using a 0-10 V module. At a temperature above 25°C, boiler heating should be stopped. The temperature is determined by means of a thermocouple. ;In order to protect the burner, it should be switched via a hysteresis function.

文档评论(0)

136****1820 + 关注
实名认证
文档贡献者

该用户很懒,什么也没介绍

1亿VIP精品文档

相关文档