Page * / 18 PC200-8 GST Nov 2005 PC200-8 Removal of head cover Remove nuts from six positions [Nut Width across flat: 13 mm] * Loosening the nut may also disengage the stud bolt. * Pull the breather pipe out first and then remove the head cover assembly. The head cover is made of plastic. Exercise care so that you do not damage it by prying it too forcefully. Removal of main harness Remove the main harness from the injector harness coupler. Remove the fuel pressure sensor from the common rail. * See Removal and Installation of Coupler for the harness removing procedure. Remove the bracket