— PAGE \* Arabic 1 —
压力表检测仪器仪表
Dead weight testers are used for examination and calibration of pressure gauges and other pressure measuring instruments without using an external instrument. The main components are the measuring system, the valve units, the built-in screw pump for accurate pressure adjustment and the set of weights. The measuring system itself consists of a precise lapped-in pair of piston and cylinder. During the measuring process the piston is forced up by the pressure produced with the built-in screw pump re-spectively with external pressure supply, while the regular weights and maybe further extra weights, if required for the designated test pressure, press it down. With the built-in screw pump the test pressure can be adjusted to an equilibrium of the forces. When the forces on both sides of the piston are in balance, the piston will be floating, and the designated test pressure is reached exactly. For simplifying the handling, the instrument-specific weights are already referred to each relevant determined piston area and stamped with the pressure unit (bar/kPa). The influence of the friction between piston and cylinder is mini-mised by keeping piston and weights rotating while floating.The models described in this data sheet are available for pressure ranges 0.1 to 6, 0.1 to 10 resp. 0.1 to 25 bar. Technical data ? Pressure range: PD 6 0.1 to 6 bar PD 10 0.1 to 10 bar PD 25 0.1 to 25 bar ? Set of weights in bar / kPa ? External pressurised air supply for PD 10 and PD 25 required, indeed as high as the pressures that have to be examined 1); external pressurised air supply for PD 6 recommended (compare page 2) ? Accuracy of the adjusted examination pressure: better 0.05 % resp. 0.03 % (with official verification or DKD-approval) referred to the effective pressure. Up to 0.6 bar the maximum error is constantly ±0.3 mbar (at 0.05%) resp. ± 0.18 mbar (at 0.03%) ? Reference condition
您可能关注的文档
最近下载
- 北京市2019年中考英语真题(含答案).pdf VIP
- 2022年新高考政治真题试卷(山东卷).pdf VIP
- 2025年最新详版征信报告个人信用报告样板模板word格式新版可编辑.docx VIP
- 辽宁省大连市甘井子区2024-2025学年上学期七年级 月考英语试卷(10月份).docx VIP
- 水土保持监督管理培训课件.pptx VIP
- 《现代汉语》各章练习题答案汇总 .pdf VIP
- 输变电工程环境保护和水土保持全过程管控培训课件.pptx VIP
- 生产建设项目水土保持方案管理办法培训课件.pptx VIP
- 培训课件_1411dxs小天鹅纯臻2.0新品1411DXS系列.pdf VIP
- 2022年内蒙古农业大学硕士研究生入学考试公共管理专业综合基础考研真题.pdf VIP
文档评论(0)