Product Safety Manual – Kinetrol Actuator/Spring Limit Switch Box
1. Introduction.
In addition to information given in Kinetrol Installation, Operating Maintenance Instructions (eg TD129
Kinetrol Actuators Springs), this Safety Manual includes instructions relating to Functional Safety to
IEC 61508-2:2010 for safety valve actuation packages typically used in industrial process plants.
A Functional Safety Assessment was completed by Sira Test Certification Ltd and a copy of the
certificate can be found at
2. Terms Abbreviations (used in this document).
• Safety: freedom from unacceptable risk.
• Functional Safety: part of the overall safety relating to the EUC and EUC control system that depends
on the correct functioning of the E/E/PE safety-related systems and other risk reduction measures.
• EUC: Equipment Under Control.
• E/E/PE: Electrical/Electronic/Programmable Electronic.
• SFF: safe failure fraction defined by the ratio of the average failure rates of safe plus dangerous
detected failures and safe plus dangerous failures.
• PVST: Partial Valve Stroke Testing.
• PFD: Probability of Dangerous Failure on Demand. Kinetrol Clear Cone
Position Monitor
• Fault tolerance: the ability of a functional unit to continue to - optional
perform a required function in the presence of faults. Kinetrol Switch Box
or PVST - optional
3 Product Arrangement.
The Figure 1 opposite shows how the quarter turn pneumatic