+ Product Safety Manual – Kinetrol Actuator/Spring Limit Switch Box
Figure 1 shows the optional Clear Cone monitor fitted which
again helps to protect the moving parts against corrosion as well as
providing improved visual position indication.
3 Functional Constraints
The device, as configured, has functional constraints in its application. These can be summarised by the
following:
The mounting of the unit to the bracket/valve should be as described on page 1 of TD129.
The air/gas supply should be as specified on page 1 of TD129
Actuator/spring operation, maintenance adjustment should be as specified on page 3 of TD129
In high vibration environmental conditions (greater than 4g @ 100Hz), contact Kinetrol for advice if vibration levels
are higher.
For operating constraints of the limit switch box (if fitted) refer to the switch box IOM as supplied or contact
Kinetrol for a copy quoting the unit serial number or part number.
For functional constraints for the Solenoid Valve, refer to valve supplier quoting their part number or if supplied by
Kinetrol refer to manual as supplied.
4 Functional Failure Modes.
The mechanical simplicity of the Kinetrol actuator design, allows a relatively straight forward analysis of the possible
failure modes of its constituent parts. Therefore the failures become very infrequent as the Functional Safety Certificate
suggests and failure of components is derived mainly from generic industry data. This ensures the design comprises
Type A components. The hardware fault tolerance is assumed zero.
The critical items that contribute most to the theoretical failure modes are:
Process Valve failure data must be taken into account for the overall valve/actuator assembly and must be obtained
from the valve manufacture.
Air supply failure with double acting version
您可能关注的文档
最近下载
- DB34_T4316-2022_皖北地区设施草莓栽培技术规程_安徽省.docx VIP
- 外研版八年级上册 Unit 3 单元测试卷答案及解析 新版 2025年新外研版八年级上册.docx
- 人教版高中数学精讲精练选择性必修二4.1 数列的概念(精练)(解析版).pdf VIP
- 输液港用无损伤针相关知识.pptx VIP
- 《尝试教学法》-公开课件.ppt VIP
- 石油化工行业安装工程预算定额说明(2019)版.docx
- 外研版八年级上册 Unit 3 单元测试卷 新版 2025年新外研版八年级上册.docx
- 2025—2026学年第一学期学校教学工作计划及序列表.doc VIP
- 高中物理电学实验专题练习(2020整理).pdf VIP
- 保洁服务管理人员安排、架构,管理方案.pdf VIP
文档评论(0)