- 1、原创力文档(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。。
- 2、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载。
- 3、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
- 4、该文档为VIP文档,如果想要下载,成为VIP会员后,下载免费。
- 5、成为VIP后,下载本文档将扣除1次下载权益。下载后,不支持退款、换文档。如有疑问请联系我们。
- 6、成为VIP后,您将拥有八大权益,权益包括:VIP文档下载权益、阅读免打扰、文档格式转换、高级专利检索、专属身份标志、高级客服、多端互通、版权登记。
- 7、VIP文档为合作方或网友上传,每下载1次, 网站将根据用户上传文档的质量评分、类型等,对文档贡献者给予高额补贴、流量扶持。如果你也想贡献VIP文档。上传文档
查看更多
24 h动态心电图联合CyPA检测在高血压性心脏病
诊断中的应用
【摘要】目的 :探讨24 h动态心电图联合亲环素A (CyPA)检测对高血压性心脏病(HHD)的诊断价值 。方法 :80例
HHD患者设为HHD组,另选取同期年龄、性别相匹配且排除心脏损伤的80例高血压患者作为对照组,均行24 h动态心电图
检査,并检测血清CyPA水平 ;比较两组动态心电图ST-T改变阳性率和血清CyPA水平,并应用受试者工作特征曲线(ROC)评
价两种检査及其联合对HHD的诊断效能 。结果 :HHD组ST-T改变阳性率、CyPA水平、CyPA阳性率均高于对照组[83.54%
vs. 11. 25% 、( 15 ±1. 37 ng/L) vs. (10. 49 ±2. 06 ng/L) ,80. 00% vs. 16. 25% , P 0. 05] o 24 h 动态心电图联合血清 CyPA 诊
断HHD的敏感度为93.75%,特异度为87.50% ,RO 曲线下面积(AUC)为0. 906,诊断效能优于各单一检査 。结 :24 h动
态心电图、血清CyPA检测联合应用可提高对HHD诊断的敏感度。
【关键词】高血压性心脏病;高血压;心脏病;24 h动态心电图;CyPA
Application of 24 h dynamic electrocardiogram combined with CyPA de
tection in diagnosis of hypertensive heart disease
[Abstract] Objective: To investigate the diagnostic value of 24 h dynamic electrocardiogram combined with cyclophilin A
(CyPA) in hypertensive heart disease ( HHD). Methods: A total of 80 patients with HHD were selected,and another 80 patients with
hypertension matched in age and gender and excluded from heart injury at the same period were selected as the control group. All pa
tients underwent 24-hour ambulatory ECG examination and the serum CyPA level was detected. The positive rate of dynamic electrocar
diogram ST-T change and serum CyPA level were compared between the two groups, and the diagnostic efficiency of the two examina
tions and their combination for HHD was evaluated by receiver operating characteristic curve ( RO ) . Results: The positive rate of ST-
T change, CyPA level and CyPA positive rate in HHD group were 83. 54% ,8. 15 ± 1. 37 ng/L and 80. 00% , respectively, which were
significantly higher than 11. 25% ,10. 49 ± 2. 06 ng/L and 16. 25% in control group (P 0. 05 ). The sensitivity of 24 h ambulatory e-
lectrocardiogram combined with serum CyPA in the diagnosis of HHD was 93. 75% , the specificity was 87. 50% , and the area under
RO curve was 0. 906. The diagnostic efficacy was better than that of each single examin
从事办公室文字工作,提供论文格式排版 、专业学术论文参考资料、文章写作、论文答辩PPT模板、会议筹备指导等服务,经验丰富,已从事七年。互相信任,保证质量,全程包修改,负责到通过。 微X号:lhg511823
文档评论(0)