* DI1: Non-programmable I/O. Reserved for the supply unit cooling air fan supervision. DI2: Non-programmable I/O. Reserved for the supply unit ON/OFF control. DI3: Non-programmable I/O. Reserved for the supervision of the main contactor/air circuit breaker state. DI4: Programmable I/O. Reserved for the external earth fault detection. For the actual use see the circuit diagrams and Parameter 30.04 DI4 EARTH FLT SEL. DI5: Programmable I/O. Reserved for the 12-pulse bridge application. For the actual use see the circuit diagrams and Parameter 47.01 REDUNDANT SEL. DI6: Non-programmable I/O. Reserved for the supply unit fault resetting DI7: Programmable I/O. Reserved for the external control of the reverse bridge (enable/disable) and/or intermediate DC circuit voltage reference. For the actual use see the circuit diagrams and Parameter 16.12 DI7 FUNCTION SEL. DI8: Programmable I/O. Reserved for the external control of the reverse bridge (enable/disable). For the actual use see the circuit diagrams and Parameter 16.13 DI8 FWD BRIDGE SEL. Grounding selection with short circuit resistors: - cut out for internal W2....W16 - cut out for external W1....W15 * - B1 to B5 are frame sizes of the TSU units. - Corresponding power see in the Technical catalogue data of the User’s Manual. * * * 2.11 RL DC CURRENT Intermediate circuit DC current in percents of the nominal value (Ic) measured every 3,3ms (50Hz supply) or 2,8 ms (60Hz supply) 2.12 RL DC VOLTAGE Intermediate circuit voltage in percents of the nominal value measured every 3,3 ms (50Hz supply) or 2,8 ms (60Hz supply) 2.13 RL MAINS VOLTAGE Supply voltage in volts measured every 3,3 ms (50Hz) or 2,8 ms (60Hz) 2.14 FIRING ANGLE Thyristor firing angle in degrees, update interval is 3,3 ms (50Hz) or 2,8 ms (60Hz). 2.15 CONV_VALUE_2MS Selected actual signal updated every 2ms. See Parameter 94.01 CONV VALUE 2MSSEL. 2.16 CONV_VALUE_8MS Selected actual signal updated every 8ms. See Parameter 94.02 CONV VALUE 8MSSEL. * 94 G

文档评论(0)

宋江 + 关注
实名认证
文档贡献者

该用户很懒,什么也没介绍

1亿VIP精品文档

相关文档