【codesys2.3培训_WAGO英文原版】Module_8_Exercises_landscape format.pptVIP

【codesys2.3培训_WAGO英文原版】Module_8_Exercises_landscape format.ppt

  1. 1、原创力文档(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。。
  2. 2、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载
  3. 3、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
  4. 4、该文档为VIP文档,如果想要下载,成为VIP会员后,下载免费。
  5. 5、成为VIP后,下载本文档将扣除1次下载权益。下载后,不支持退款、换文档。如有疑问请联系我们
  6. 6、成为VIP后,您将拥有八大权益,权益包括:VIP文档下载权益、阅读免打扰、文档格式转换、高级专利检索、专属身份标志、高级客服、多端互通、版权登记。
  7. 7、VIP文档为合作方或网友上传,每下载1次, 网站将根据用户上传文档的质量评分、类型等,对文档贡献者给予高额补贴、流量扶持。如果你也想贡献VIP文档。上传文档
查看更多
EXERCISE 1Write a program with the following functionFirst program in FBDS3S1S2K0 EXERCISE 2Write a program with the following functionFirst program in CFCS3S1S2K0 EXERCISE 3Write a program with the following functionFirst program in LDS3S1S2K0 EXERCISE 4Write the program in FBD or CFCProgram in FBD or CFCS1S8S5K1S4S3S2S6S7 EXERCISE 5Now please program the circuit diagram in LDProgram in LDS1S8S5K1S4S3S2S6S7 EXERCISE 6Add an ON delay for output K2 with a 4.75 s delay time to the program from Exercise 4Program with a TimerS1S8S5K1S4S3S2S6S7K1Timer1K2Timer1 EXERCISE 7With the aid of two “TP” function blocks, program a flashing light that flashes at a clock rate of 100 ms.Flashing LightTPTPtimetimeQ EXERCISE 8Parking Garage EXERCISE 9Conveyor BeltGenerate a PLC_VISU with the elements depicted. The system is switched using S1 to “RUN” and using S2 to “STOP”.Using S3 simulates the “light sensor” that is used for counting the parts.The “engine” runs as long as the counter has not reached the value 5 and the system is set to “RUN”. The counter could be reseted by using S4 (container changed). EXERCISE 10BoilerRealize a boiler control by means of which a water boiler can be filled and heated. The system should be started/ stopped using a start/ stop button. At a filling level of 4000 liters, the valve should be closed. The fill level is determined using a 0-10 V module. At a temperature above 25°C, boiler heating should be stopped. The temperature is determined by means of a thermocouple. EXERCISE 10.1In order to protect the burner, it should be switched via a hysteresis function. Addition25°C20°COffOn30°C 恭祝马到成功

文档评论(0)

ljszhw1972 + 关注
实名认证
文档贡献者

天津大学硕士、一级建造师,愿与大家共享经验与文档

版权声明书
用户编号:7153166103000005

1亿VIP精品文档

相关文档