- 1、原创力文档(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。。
- 2、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载。
- 3、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
- 4、该文档为VIP文档,如果想要下载,成为VIP会员后,下载免费。
- 5、成为VIP后,下载本文档将扣除1次下载权益。下载后,不支持退款、换文档。如有疑问请联系我们。
- 6、成为VIP后,您将拥有八大权益,权益包括:VIP文档下载权益、阅读免打扰、文档格式转换、高级专利检索、专属身份标志、高级客服、多端互通、版权登记。
- 7、VIP文档为合作方或网友上传,每下载1次, 网站将根据用户上传文档的质量评分、类型等,对文档贡献者给予高额补贴、流量扶持。如果你也想贡献VIP文档。上传文档
查看更多
鸡胚绒毛尿囊膜数字图像血管定量分析*
琚立华1,胡 平2,倪 爽3
Quantitative analysis of blood vessels in chick embryo chorioallantoic membranes through digital imaging
Ju Li-hua1, Hu Ping2, Ni Shuang3
Abstract
AIM: To study the method for automatic analysis of blood vessels in digital chick embryo chorioallantoic membrane (CAM) images and develop a special experimental analysis system based on digital image processing and biomedical engineering.
METHODS: The experiment was performed at the Central Laboratory of School of Medical Instrument and Food Engineering, University of Shanghai for Science and Technology, and Shanghai University of Traditional Chinese Medicine from June 2005 to June 2007. Based on the characteristics of CAM images, the image analysis software and hardware were studied and developed. The main functions of the analysis software included CAM image background fading, blood vessels enhancement, background and blood vessel calibration, measurement region division, micro-ruler calibration, blood vessel area and area ratio measurement and so on. The analysis method and measurement parameters were tested by experiments, and the analysis system was improved during that process.
RESULTS: The analysis method and procedure as well as the analysis system for CAM image were efficiently established. The parameter measurements in CAM images from drug experiments in which the animals were divided into several groups were executed. The data obtained from the experiments were statistically analyzed. The result of statistical analysis indicated that the tested drug could restrain the growth of blood vessels in a dose-dependent manner.
CONCLUSION: The method and the system are reliable for the analysis and can provide quantitative data from CAM model. It is also better than conventional method of blood vessel count from CAM images by microscope in analysis speed, precision and data reproducibility.
Ju LH, Hu P, Ni S.Quantitative analysis of blood vessels in chick embryo chorioallantoic
文档评论(0)