- 6
- 0
- 约 4页
- 2015-08-29 发布于重庆
- 举报
深覆_乳牙列的测量和分析_计算机牙_模型测量仪的应用.pdf
18 Shan hai M ed J , 2001, Vol. 24, No. Suppl
邓清 石四箴
, ;
, ( 59 ) , ( 6 1 )
( P 0. 05) ,
, ;
,
; ;
Measurement and analysis of deep overbite primary dentition with computeraided measuring device DEN G
Qing , SHI Siz hen I nstitute of Pediatr ic D entistry , Tongj i Univ ers ity , Shanghai, 200072
Abstract Objective T o study the trait of deep overbite primary dent ition for providin a reference for clinical
pract ice and to introduce a device for dental casts measurement. Methods A series of 120 primary dentition casts ( 59
normal dentitions, 6 1 deep overbite dentitions) were collected, and classified into normal roup and deep overbite roup
accordin to the occlusion type. The tw o roups were measured w ith the computeraided device. The data of measure
ment w ere analysed statistically. Results T he mean values of the hei ht of dentition and upper dental arch len th of
deep overbite primary dentition were smaller than t hat of normal primary dentition, so did lower dental arch w idth and
len th ( P 0. 05) . Conclusion The computeraided measurin device which can increase simplicity , accuracy and in
formatics of dental cast measurements is more reproducible than the Vernier a ue. The difference betw een normal and
deep overbite primary dent ition has effected on the health of the children, so the dentist should pay more attention to
t he deep overbite primary dentition. ( Shan hai Med J, 200 1, 24Suppl 1821)
Key words Primary dentition; Normal occlusion; deep overbite occlusion
, Grosfeld 38%~
51% , 43. 68%~ 20. 90% [ 1, 2] 1/ 3, 3mm
, ,