- 1、本文档共16页,可阅读全部内容。
- 2、原创力文档(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。
- 3、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载。
- 4、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
查看更多
Determination of source parameters of small earthquakes from Pwave rise time
Bulletin of the Seismological Society of America. Vol. 63. No. 2, pp. 599-614. April 1973
DETERMINATION OF SOURCE PARAMETERS OF SMALL
EARTHQUAKES FROM P-WAVE RISE TIME*
M. E. ONEILL AND J. H. HEALY
ABSTRACT
A simple method of estimating source dimensions and stress drops of small
earthquakes is presented. The basic measurement is the time from the first break
to the first zero crossing on short-period seismograms. Graphs relating these
measurements to rise time as a function of Q and instrument response permit an
estimate of earthquake source parameters without the calculation of spectra.
Tests on data from Rangely, Colorado, and Hollister, California, indicate that
the method gives reasonable results.
INTRODUCTION
This paper is the result of a search for methods to determine both Q and the source
parameters of small earthquakes using data recorded on standard instruments. The ideal
data for studying source parameters would be recorded on instruments having a wide
dynamicrange and a broad-band frequency response. Such instruments exist (Tucker and
Brune, 1972), but they are expensive and difficult to operate in large numbers. The systems
that are now used routinely for studies of small earthquakes have a dynamic range of less
than 40 db, two ordersof magnitude, and a reasonably fiat frequency response between
1 and 25 to 30 Hz. If the gains on a network are set to detect earthquakes of magnitude 0,
the signals from earthq
您可能关注的文档
- An+Analysis+on+the+Definition+of+Culture.pdf
- Analysis and control of the nearwake flow over a squareback geometry.pdf
- Analysis and Design of a LowStress BuckBoost Converter in UniversalInput PFC Application.pdf
- Analysis of a hollow core photonic bandgap fiber ring resonator based on microoptical structure.pdf
- Analysis of a prophage gene frequency revealed population variation of Las.pdf
- Analysis of a Physician Tool for Evaluating Dysphagia on an Inpatient Stroke Unit The Modified Mann.doc
- Analysis of a Large StructureBiological Activity Data Set Using Recursive Partitioning and.pdf
- Analysis of advanced gas foil bearings with piecewise linear elastic supports.pdf
- Analysis of biomass pyrolysis liquids separation and characterization of phenols.pdf
- Analysis of closedloop control of parallelplate electrostatic microgrippers.pdf
文档评论(0)