NonRectangular Shaping and Sizing of Soft Modules for Floorplan Design Improvement.pdfVIP

NonRectangular Shaping and Sizing of Soft Modules for Floorplan Design Improvement.pdf

  1. 1、原创力文档(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。。
  2. 2、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载
  3. 3、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
  4. 4、该文档为VIP文档,如果想要下载,成为VIP会员后,下载免费。
  5. 5、成为VIP后,下载本文档将扣除1次下载权益。下载后,不支持退款、换文档。如有疑问请联系我们
  6. 6、成为VIP后,您将拥有八大权益,权益包括:VIP文档下载权益、阅读免打扰、文档格式转换、高级专利检索、专属身份标志、高级客服、多端互通、版权登记。
  7. 7、VIP文档为合作方或网友上传,每下载1次, 网站将根据用户上传文档的质量评分、类型等,对文档贡献者给予高额补贴、流量扶持。如果你也想贡献VIP文档。上传文档
查看更多
NonRectangular Shaping and Sizing of Soft Modules for Floorplan Design Improvement

Non-Rectangular Shaping and Sizing of Soft Modules for Floorplan Design Improvement Chris C.N. Chu and Evangeline F.Y. Young Abstract Many previous works on floorplanning with non-rectangular modules [8, 13, 4, 5, 6, 3, 10, 11, 12, 1, 15, 2] assume that the modules are pre-designated to have particular non-rectangular shapes, e.g., L-shaped, T-shaped, etc. However, this is not common in practice because rectangular shapes are more preferable in many designing steps. Those non-rectangular shapes are actually generated during floor- planning in order to further optimize the solution. In this paper, we study this problem of changing the shapes and dimensions of the flexible modules to fill up the unused area of a preliminary floorplan, while keeping the relative positions between the modules unchanged. This feature will also be useful in fixing small incremental changes during ECO modifications. We formulate the problem as a mathematical pro- gram. The formulation is such that the dimensions of all the rectangular and non-rectangular modules can be computed by closed form equations in O (m) time where m is the total number of edges in the constraint graphs. Experimental results show that the amount of area re-used is 3.7% on average while the total wirelength can be reduced by 0.43% on average because of the more compacted result packing. 1 Introduction A lot of previous works have then been reported on floorplanning with non-rectangular blocks [13, 3, 4, 5, 10, 11, 12, 6, 1, 15, 2, 7]. The papers [14, 3] extend the Polish expression representation for slicing floorplans to handle L-shaped and T-shaped modules. The works on non-slicing floorplans are mostly based on the Bounded Sliceline Grid (BSG) structure [4, 5, 10, 11, 12] or the Sequence Pair (

文档评论(0)

yaobanwd + 关注
实名认证
文档贡献者

该用户很懒,什么也没介绍

1亿VIP精品文档

相关文档