Previous Page 164 BASIC THERMAL DESIGN THEORY FOR RECUPERATORS then indicates the number of shells required (three for Fig. 3.18) to avoid the temperature cross in the exchanger. Thus with this procedure, there is no need to conduct a detailed thermal analysis to find out how many shells are required in series to avoid the tempera- ture cross. 3.6.2 Multipass Exchangers A multipass exchanger, defined at the beginning of Section 1.6, is a single exchanger having multipassing of one or both fluids in the exchanger. A heat exchanger a